23
TeeJet 734 Switch Box - Back
TeeJet 734 Switch Box - Back (open)
TeeJet 734
If you have ordered a Spraying Systems TeeJet 734 Custom
Harness Kit, you will be supplied with an adapter cable, relay
board, 14” nylon ties and two RED jumper wires.
INSTRUCTIONS
1. Locate the black cable tie on the back of the box.
See
Illustration 26.
Cut the tie, being sure not to cut any
wires. Pop the front panel of the TeeJet 734 off. Pull the
front panel and mesh cable jacket forward to provide
adequate working space and accessibility. Feed the 24”
RED jumper wire through mesh cable jacket and into
box (female spade terminal end). Plug the RED jumper
wire onto terminal C on the relay board (male 90û spade
terminal end).
See Illustration 25.
2. Unplug the red wire on the bottom of the master
switch and plug into terminal A on the relay board.
See Illustration 25.
3. Plug one end of the 6” RED jumper wire supplied with
the kit to the bottom terminal of the master switch.
Plug the other end to terminal B on the relay board.
See Illustration 25.
4. With all wires connected properly, remove the protective
paper from the double-stick tape on the relay board
and stick the relay board to the back of the front
panel between the master switch and the increase/
decrease switch.
See Illustration 27.
Tuck wires into
box, making sure wires are not being pinched behind
pressure gauge.
5. Carefully place cables and front panel back into box and
pop front panel back into place.
NOTE: The pressure adjust function on the switch box
should be used as a throttle valve ONLY. Once the throttle
valve is set, use the “+” and “-” buttons on the MT-2400
when making rate changes in automatic mode or when
spraying in manual mode.
TeeJet 734 Switch Box - Front
Cable Tie
Illustration 25
Relay Board
Terminal A
Terminal B
Terminal C
Installation
(cont)
Optional Switch Box Harness
(cont)
Illustration 26
Illustration 27