21
All Calc-An-Acre II consoles are tested prior to packaging,
so unless there has been damage in shipment you can be
confident that everything will be operational when you
receive it.
However, if you do encounter a problem that appears to be
related to equipment failure,
PLEASE DO NOT OPEN THE
CONSOLE.
Your system is protected by a warranty, and
Micro-Trak will gladly correct any defect.
Problems can be the result of mistakes in installation
or operation. Before returning any parts for service,
carefully check your installation and review the operating
instructions.
For easy-to-follow guidelines, refer to the
troubleshooting section which follows.
CONSOLE APPEARS DEAD
Using your test light, check for 12 volts at the power source.
Also check for damaged power cable or reversed terminals.
(Console requires 12 volts for proper operation).
SPEED IS ALWAYS ZERO OR ERRATIC
Check for properly calibrated speed cal number.
Review speed sensor installation. Check for proper
mounting, alignment and spacing of speed sensor in
relationship to magnet assembly. Make sure magnet
polarities are alternated. Also check cable for breaks or
incomplete connection.
For more suggestions on solutions to speed problems, see
Hall-effect sensors and console inputs on pages 23.
DISTANCE COUNT IS INACCURATE
Speed cal number was incorrectly calculated or entered.
Review calibration, re-adjust and test.
AREA COUNT IS INACCURATE
Working width or wheel circumference was measured
incorrectly, or speed cal number was incorrectly calculated
or entered. Go back through the original procedures, make
changes, and test for acre (hectare) count again. Verify
accuracy with formula:
Acres = Distance x Width in feet/43560
Hectares = Distance x Width in meters/10,000
Thousands of square feet = Distance x Width in feet/1000
CONSOLE IS ERRATIC IN OPERATION
If you have a two-way radio, it may be mounted too close
to the console. Keep all Calc-An-Acre II cables away from
the radio, its antenna and power cable.
Ignition wires may be causing the console to malfunction.
Keep Calc-An-Acre II cables away from ignition wires, or
install ignition suppressor.
Reroute all cable away from electric solenoids, air
conditioning clutches and similar equipment.
DISPLAYED MEASUREMENTS DO NOT MAKE SENSE
The console may be in the incorrect measurement mode
(English or metric).
See page 15 for instructions
.
DISPLAY READS “OFL”
DISTANCE, AREA, TOTAL HOURS and SUB HOURS counters
read OFL when they have exceeded their maximum count.
Reset to zero to resume counting.
Troubleshooting
(cont)
General
Содержание Calc-An-Acre II
Страница 1: ......
Страница 24: ...24 Appendices ...