Page 2
scanCONTROL 2910/2960BL
4.
Laser Safety
The Sensoren scanCONTROL 2910/2960-xx/BL operate with a semiconductor laser
with a wavelength of 405 nm (visible/blue)
.
Operation of the laser is indicated visually
by the LED on the sensor, see operating instructions, Chap. 3.3.
When operating the scanCONTROL 29xx sensors, the relevant regulations according to
IEC 60825, Part 1 of 05/2014 and the applicable accident prevention regulations must
be followed.
The laser warning labels for Germany have already been attached. For other non Ger-
man speaking countries, an IEC standard label is included in delivery and the versions
valid for the user‘s country must be attached before the device is put into operation for
the first time.
i
If both warning labels are covered over when the unit is installed, the user must
ensure that supplementary labels are applied.
Laser radiation. Close your eyes or immediately turn away if the
laser beam hits the eye. Irritation or injury of the eyes possible.
Laser Class 2M
The sensors fall within laser class 2M. The laser is operated on a pulsed mode, the
maximum optical power is ≤ 8 mW (scanCONTROL 29xx-10/BL ≤ 7 mW). Attach the
following warning labels to the cover (front and rear side) of the sensor housing:
Laser warning sign and laser label, LLT 29xx-25/BL, 29xx-50/BL, 29xx-100/BL
7
7
6
Laser warning sign and laser label, LLT 29xx-10/BL
Mark the laser area recognizable and everlasting.