Page 20
optoCONTROL 1202
I
100 mA
L
e.g. SCD1202-2
e.g. CE1202-5
e.g. SCA1202-2
white (Ground)
brwon (+15 ... +30 VDC, e.g. PS2020)
blue (OUT2)
pink (OUT1)
red (0 ... 10 V, measurement signal)
gray (OUT0)
V
yellow (IN1)
green (IN0)
ODC1202-x-T (Transmitter)
ODC1202-x-R (Receiver)
1
Fig. 7 Typical wiring of transmitter, receiver, control the digital input IN1 and the digital output OUT0
Bending radii cables:
SCD1202-x / SCA1202-x / CE1202-x: minimal 80 mm flexible or 53 mm fixed
1) High side/low side switch. Drives the load in direction to power supply or to ground.