Page 113
Anhang | API Communication with Controller (Version 0.7.1)
colorSENSOR CFO
A 3.5.3.30 /api/sensor/recognition-profiles/(UUID|current)/autogain
POST
Triggering of automatic level adjustment with following (optional) parameters:
Attribute
Model
Default value
Content
level
Floating-point
number
0.8
Target value for level adjustment
(between 0 and 1)
minimum_sample_
rate
Floating-point
number
Current sample rate
(or 1000)
Desired sample rate
enable_internal_
emitter
Floating-point
number
true
Activate or
switch off internal light source
Error codes:
LCOL.autogain
LCOL.autogain.invalid_target_level
LCOL.autogain.invalid_sample_rate
LPLC.validation.boolean
A 3.5.3.31 /api/sensor/recognition-profiles/(UUID|current)/white-reference
GET
Read out non-factory white reference
POST
Set white reference (without parameters; current sample is used)
DELETE
Deletion is permissible. (Reset white reference to factory state)
Error codes:
LCOL.white_reference.too_dark