MCS-THERMOSTAT 

REVISION 1.5

7

3.  Icons Display

  

Unit has an active alarm.

 

Unit is in cooling mode.

 

Unit is in dehumidification mode.

 

Evaporate fan is running (speed indicator low, medium, high).

 

Unit is in heating mode.

 

Outside air damper is closed.

 

Outside air damper is open.

Thermostat is locked-no changes allowed without Authorization.

Up arrow key.

Down arrow key

Enter arrow key

 

Override button-takes unit out of unoccupied (set point based)

 

Unit is in unoccupied mode.

 

Day of week icons. 

LOW MED HIGH

MO -MONDAY 

FR-FRIDAY

TU-TUESDAY SA-SATURDAY

WE-WEDNESDAY SU-SUNDAY

TH-THURSDAY

Содержание MCS-THERMOSTAT

Страница 1: ...your Control Needs Energy Efficient and RoHS Compliant 5580 Enterprise Pkwy Fort Myers FL 33905 Office 239 694 0089 Fax 239 694 0031 www mcscontrols com Installation Reference Guide Version 1 5 MCS TH...

Страница 2: ...provisions shall be provided to ensure that this information remains proprietary by your employees agents and other personnel that may have access to this document Copyright 2016 Date Author Descripti...

Страница 3: ...1 13 9 1 2 Units Degrees F Or C 13 9 1 3 Auth Level Setup 13 9 1 4 Sound Alarm Stat 13 9 1 5 Adjust Backlight 13 9 1 6 Standby Backlight 13 9 1 7 Exit Setup Menu 13 9 2 MAIN 13 9 2 1 Unit Status 13 9...

Страница 4: ...POINT 16 11 6 HEAT SET POINT 16 11 7 HUMIDITY SET POINT 16 11 8 CO2 SETPOINT 16 11 9 VERSION NUMBER 16 11 10 TIME AND DATE 16 11 11 LAST LOCKOUT ALARM 16 11 12 LOCKOUT RESET 16 12 Config Menu Setting...

Страница 5: ...ules holiday schedules calibration and password protection Menu Access the primary menu Override Permits override Room is occupied Room is unoccupied Enter Confirms changes and adjustments Selection U...

Страница 6: ...nit is in DEHUMIDIFICATION Indicates position of outside Air Damper Indicates Speed of FAN Low Medium High Thermostat is LOCKED An ALARM is ACTIVE Display shows current views OCCUP Occupied UNOCCUP Un...

Страница 7: ...Unit is in heating mode Outside air damper is closed Outside air damper is open Thermostat is locked no changes allowed without Authorization Up arrow key Down arrow key Enter arrow key Override butt...

Страница 8: ...lt power supply 4 2 MOUNTING LOCATION Install the MCS THERMOSTAT on an interior wall Exterior walls that are poorly insulated can affect the Thermostat temperature and humidity readings and may lead t...

Страница 9: ...ional Style Junction Box USA Style Junction Box International USA Puncture a small hole in the grommet on the back side of the thermostat You want the wires to be tight so no air passes through affect...

Страница 10: ...iring diagram below ONE THERMOSTAT PER MCS CONTROLLER TURN POWER OFF TO CONTROLLER AND THERMOSTAT FIRST MCS THERMOSTAT Enlarged view of Thermostat block wiring MicroMag Sensors 5 Sensors available Pow...

Страница 11: ...wiring diagram below ONE THERMOSTAT PER MCS CONTROLLER TURN POWER OFF TO CONTROLLER AND THERMOSTAT FIRST MCS THERMOSTAT Enlarged view of Thermostat block wiring MicroMag Sensors 5 Sensors available Po...

Страница 12: ...agram below ONE THERMOSTAT PER MCS CONTROLLER TURN POWER OFF TO CONTROLLER AND THERMOSTAT FIRST MCS THERMOSTAT Enlarged view of Thermostat block wiring MAGNUM Sensors 12 Sensors available Power for Th...

Страница 13: ...et 9 3 CONFIG MENU 9 3 1 Auth Level Setup 9 3 2 Units F C 9 3 3 Modify Schedules 9 3 4 Modify Holidays 9 3 5 Temp Cal 9 3 6 Humidity Cal 9 3 7 Display Test 9 3 8 Adjust Backlight 9 3 9 Standby Backlig...

Страница 14: ...The user will be able to see all funtions of the thermostat if the controller s configuration file is setup to allow this Some functions of the thermostat may be turned off in the configuration file t...

Страница 15: ...CESS TO THE THERMOSTAT WHEREAS AUTHORIZATION LEVEL FACTORY WILL HAVE THE HIGHEST AUTHORIZATION FOR MAKING CHANGES TO THE THERMOSTAT YOU CAN SET UP THE AUTHORIZATION LEVEL FOR EACH SELECTION SHOWN IN T...

Страница 16: ...ET POINT Hit ENTER Allows the user to SET THE HEAT SET POINT FOR THE AREA 11 7 HUMIDITY SET POINT Hit ENTER Allows the user to SET THE HUMIDITY SET POINT FOR THE AREA 11 8 CO2 SETPOINT Hit ENTER Allow...

Страница 17: ...ng only Think of the Thermostat SCHEDULES as controlling whether a building or room is OCCUPLIED or UNOCCUPLIED We can still allow the building or room to be cooled or heated but with target setting w...

Страница 18: ...ing screen will appear Prs Enter to continue The information will be sent to the controller 5 Be sure to set the START and END TIMES for each day for SCHEDULE 1 and for SCHEDULE 2 before proceeding to...

Страница 19: ...rea Directions Use the Up Down arrows to move between the offset range Press Enter to select the desired temperature offset and the display will confirm the change 12 7 DISPLAY TEST Allows the user to...

Страница 20: ...HERMOSTAT 1 REMOVE COVER FROM THERMOSTAT AND REMOVE THE WIRES FROM THE PLUS AND MINUS FOR THE COMMUNICATION OF THE THERMOSTAT 2 CONNECT THE TERMINAL BLOCK SUPPLIED TO THE THERMOSTAT WHITE WIRE TO PLUS...

Страница 21: ...onnect screen opens a red line will appear on the site info showing the Software information of the MCS Thermostat 8 While on the site info screen press Load Firmware and select the location for the n...

Страница 22: ...u to make sure you have the proper Unit Degrees chosen Celsius or Fahrenheit Reset the Temp Calibration using the Config Menu to adjust for temperature variations THERMOSTAT ICONS TEST To make sure al...

Отзывы: