VDL S7‑300 U
Ser
M
anUaL
32
M
icro
‑A
ide
3
Network Setup
-------------
IP Address 192.168. 0.100
Subnet Mask 255.255.255. 0
Gateway 0. 0. 0. 0
Ethernet MAC Address 00-08-DC-01-23-45
Port 5000
TCP/IP mode Raw TCP/IP
Network Command
A description of each field follows.
ip a
DDreSS
The IP Address must be set in accordance with the requirements of the LAN or the same as the address
used by the TCP / IP connection of the PC. The initial setting is typically 192.168.0.100.
S
Ubnet
M
aSK
The Subnet Mask must also be set in accordance with the requirements of the LAN. A value of
255.255.255.0 should be acceptable for a directly connected PC. The initial setting is typically
255.255.255.0.
g
ateWay
If a Gateway is being used by the LAN it too must be set in accordance with the LAN requirements. A
setting of 0.0.0.0 is acceptable for a directly connected PC or a LAN when communications through a
Gateway are not required. The initial setting is typically 0.0.0.0.
e
thernet
MaC a
DDreSS
The first three numbers that comprise the MAC Address must be 00‑08‑DC. They must not be changed as
they are uniquely associated with the Ethernet module used by the VDL. The remaining three numbers
must not be shared by any other Ethernet device on the LAN. The initial setting is 00‑08‑DC‑aa‑bb‑cc,
where aa‑bb‑cc is the serial number assigned by MICRO‑AIDE to the logger. By way of example, a VDL
with a serial number of 12345 will have a factory assigned MAC Address of 00‑08‑DC‑01‑23‑45. This ad‑
dress is guaranteed to be unique.
Use extreme caution in modifying the logger’s MAC Address. Serious LAN conflicts will be created if dupli
‑
cate MAC Addresses are allowed to exist. Also, restoring a Setup Database will alter the MAC Address if
the saved database includes a different MAC Address.
p
ort
The Port assignment must also be selected in accordance with the requirements of the LAN. For a di‑
rectly connected PC any value greater than 1024 is acceptable. The initial setting is typically 5000.
tCp / ip M
oDe
A Selection Field is used to assign the TCP / IP Mode setting. Press the
Spacebar
to select either Raw
TCP / IP or Telnet. Generally, the Raw TCP / IP setting is acceptable. However, the Telnet setting must be
used when the Setup Database is being uploaded or downloaded using HyperTerminal. These data
transfers rely upon the Xmodem protocol which always deals with binary data. To insure data transpar‑
ency, Telnet mode must be selected for all Xmodem transfers. Raw TCP / IP is the initial setting.
Press the
Esc
key after all of the fields are properly defined. The following message will be displayed if the
MAC Address was altered.
CHANGE MAC ADDRESS (normally 00-08-DC-xx-xx-xx), are you SURE?
No Yes
Select Yes to proceed. Finally, the following message will confirm the change(s) to be made.
Содержание CWR-24E
Страница 2: ......
Страница 14: ...VDL S7 300 User Manual 6 Micro Aide 1 User Notes ...
Страница 22: ...VDL S7 300 User Manual 14 Micro Aide 2 User Notes ...
Страница 96: ...VDL S7 300 User Manual 88 Micro Aide A User Notes ...
Страница 98: ...VDL S7 300 User Manual 90 Micro Aide B User Notes ...
Страница 106: ...VDL S7 300 User Manual 98 Micro Aide C User Notes ...