Time / Date Command
Time/Date
HH:MM:SS
Time: 16:20:59
MM-DD-YY
Date: 02-20-14 Thursday
The highlight may be moved to the hour, minute or second time fields or month, day or year date fields.
The VDL utilizes a military‑style clock. Accordingly, 12:01:02 AM is defined as 00:01:02 and 12:59:58 PM is
defined as 23:59:58. Leading zeros are not required. The day of week is displayed automatically as deter
‑
mined by the date selected by the user.
To complete the command press the
Esc
key. The user can then accept or abandon the changes.
The clock of the VDL can be precisely controlled by three different means. The Clock Sync Mode can
be set to GPS or SNTP. Either of two SNTP methods are available. Refer to the section entitled
“Clock Sync
Mode” on page 22
. If the clock cannot be synchronized MICRO‑AIDE recommends that the clock be
manually set once per month.
r
eSet
S
ySteM
(r)
The Reset System command can be used at any time to restore the logger to its factory default settings.
The command can also be used to clear previously logged Event Records. This step is listed as part of
the Setup Procedure since it can be useful in restoring the logger to a known state consistent with this
documentation. Additionally, any programming or Event Records created as a part of the Initial Check‑
Out Procedure will be erased.
The following menu will be displayed after executing the Reset System command. Both command op‑
tions are described in the sections that follow.
Reset System Command
Reset System
S Reset Setup Data
E Reset Event Memory
B Reset Both
The time and date settings, along with the Network and several System Parameters, are not affected by
either option of the Reset System command.
r
eSet
S
etUp
D
ata
(S)
The VDL utilizes two non‑volatile memories. The first, referred to as the Setup Database, contains all of the
programmed parameters established by the user. Most of these parameters can be restored to their fac‑
tory default values by executing the Reset Setup Data command.
Table 3 on page 18
lists the values
after the reset is performed. Some parameters are unchanged by the reset.
Parameter
Default or Reset Value
Time / Date
(as previously assigned)
Event Names ‑ On
On (1 ‑ 19), Violate (20)
Event Names ‑ Off
Off (1 ‑ 19), Nominal (20)
Input Names ‑ Digital Inputs
Digital Input 001, Digital Input 002, etc.
Input Names ‑ Analog Inputs
Analog Input 01, Analog Input 02, etc.
Input Names ‑ Virtual Inputs
Virtual Input 01, Virtual Input 02, etc.
Input Names ‑ Timer Inputs
Timer 01, Timer 02, etc.
Table 3: Factory Default / Reset Settings
Содержание CWR-24E
Страница 2: ......
Страница 14: ...VDL S7 300 User Manual 6 Micro Aide 1 User Notes ...
Страница 22: ...VDL S7 300 User Manual 14 Micro Aide 2 User Notes ...
Страница 96: ...VDL S7 300 User Manual 88 Micro Aide A User Notes ...
Страница 98: ...VDL S7 300 User Manual 90 Micro Aide B User Notes ...
Страница 106: ...VDL S7 300 User Manual 98 Micro Aide C User Notes ...