
XTC601 User’s Manual
58
97400 Issue 6.1, November 2020
APPENDIX E
Addr Function
APP
SW
Ranges/
Resolution
Type
Firmware
definition
56
Field Cal 2 Reference High
R/W
0.00–100.00
G
FIELD_REF2_HI
57
Field Cal 2 Reference Low
R/W
0.00–100.00
G
FIELD_REF2_LO
58
Field Cal 3 Reference High
R/W
0.00–100.00
G
FIELD_REF3_HI
59
Field Cal 3 Reference Low
R/W
0.00–100.00
G
FIELD_REF3_LO
60
Field Cal 1 Actual High
R
0.00–100.00
G
FIELD_ACT1_HI
61
Field Cal 1 Actual Low
R
0.00–100.00
G
FIELD_ACT1_LO
62
Field Cal 2 Actual High
R
0.00–100.00
G
FIELD_ACT2_HI
63
Field Cal 2 Actual Low
R
0.00–100.00
G
FIELD_ACT2_LO
64
Field Cal 3 Actual High
R
0.00–100.00
G
FIELD_ACT3_HI
65
Field Cal 3 Actual Low
R
0.00–100.00
G
FIELD_ACT3_LO
67
Alarm Configuration
R/W
See Reg Details
L
ALARM_TYPES
78
Last Cal Date DATE/MONTH
R
1–31/1–12
J
CAL_DATE_
DDMM
79
Last Cal Date: Field or Factory
(bit 15) / YEAR (bits0–3)
R
0=Factory, 1=Field /
0–99
J
CAL_DATE_YY
80
Hours of Operation
R
0–65535
A
HOURS_USED
82
Set Clock HRS
W
00–23
J
SET_RTC_HRS
83
Set Clock MIN
W
00–59
J
SET_RTC_MIN
84
Set Clock DAY
W
01–31
J
SET_RTC_DAY
85
Set Clock MONTH
W
01–12
J
SET_RTC_MONTH
86
Set Clock YEAR
W
00–99
J
SET_RTC_YEAR
87
% Reading of Gas
R
-199.00–199.99%
G
GAS_READING
88
Cell Temperature
R
-99.9–99.9 or
equivalent in F or K
F
CELL_TEMPR
89
PCB temperature
R
-99–99°C or
equivalent in F or K
K
INT_TEMPR
90
mA1 Input in % (phase indicator
signal)
R
0.0–100.0%
F
MA_IN1_PERC
91
mA2 Input (ext sensor signal)
R
See Reg Details
F
MA_IN2_VAL
92
Status Flags register
R
0–65535
I
STATUS_REG
93
Clock HOURS/MIN
R
00–23 / 00–59
J
RTC_HRS_MIN
94
Clock SEC/DAY
R
00–59 / 01–31
J
RTC_SEC_DAY
95
Clock MONTH/YEAR
R
0–12 / 00–99
J
RTC_MONTH_
YEAR
96
% MINIMUM (stats)
R
-199.00–199.99%
G
RM_XTCSTAT_
MIN
97
% MAXIMUM (stats)
R
-199.00–199.99%
G
RM_XTCSTAT_
MAX
99
Firmware Version
R
0.00–200.00
G
FIRM_VER
105 % without field cal correction
R
-199.00–199.99%
G
XTC_NO_
FIELDCAL
Содержание XTC601
Страница 1: ...XTC601 Binary Gas Analyzer User s Manual 97400 Issue 6 1 November 2020...
Страница 52: ...XTC601 User s Manual 42 97400 Issue 6 1 November 2020 APPENDIX A Appendix A Technical Specifications...
Страница 56: ...XTC601 User s Manual 46 97400 Issue 6 1 November 2020 APPENDIX B Appendix B Dimensional Drawings...
Страница 58: ...XTC601 User s Manual 48 97400 Issue 6 1 November 2020 APPENDIX C Appendix C Thermal Conductivity Table...
Страница 66: ...XTC601 User s Manual 56 97400 Issue 6 1 November 2020 APPENDIX E Appendix E Modbus Register Map HCG version...
Страница 73: ...XTC601 User s Manual Michell Instruments 63 APPENDIX F Appendix F Hazardous Area Certification...
Страница 80: ...http www michell com A PST Brand www ProcessSensing com...