Easidew Online User’s Manual
20
97094 Issue 18.5, March 2016
INSTALLATION
2.13.2 Transmitter Mounting - Direct Pipeline Connection
The transmitter may be directly mounted into a pipe or duct, as shown in
Figure 19.
CAUTION: Do not mount the transmitter too close to the
bottom of a bend where any condensate in the pipeline
might collect and saturate the probe.
The pipe or duct will require a thread to match the transmitter body thread. Fixing
dimensions are shown in
Figure 19. For circular pipework, to ensure the integrity of a
gas tight seal, a mounting
fl
ange will be required on the pipework in order to provide a
fl
at surface to seal against.
The following procedure must be carried out by
competent personnel.
1.
Ensure that the blue protective cover (and its desiccant capsule) has been
removed from the tip of the transmitter.
WARNING: Under no circumstances should the
sensor guard be handled with the
fi
ngers.
2.
Fit a bonded seal (2) over the threaded part of the transmitter body.
3.
Screw the transmitter (3) into the pipe (1). Tighten enough to obtain a
gas tight seal. (Torque will depend upon the pipeline material.)
NOTE: Do
not overtighten or the thread on the pipework may be stripped.
1
1
2
2
3
48
mm
3
Figure 19
Transmitter Mounting - Pipe or Duct
Содержание Easidew Online
Страница 52: ...Easidew Online User s Manual 44 97094 Issue 18 5 March 2016 APPENDIX A Appendix A Technical Specifications ...
Страница 58: ...Easidew Online User s Manual 50 97094 Issue 18 5 March 2016 APPENDIX C Appendix C EC Declaration of Conformity ...
Страница 59: ...Easidew Online User s Manual Michell Instruments 51 APPENDIX C Appendix C EU Declaration of Conformity ...
Страница 67: ...Easidew Online User s Manual Michell Instruments 59 NOTES ...
Страница 68: ...http www michell com ...