26
Operator's Manual
maintenance
delime coil:
A loss in pressure may signify that the coil needs to be delimed. Do this pro-
cedure on a periodic basis.
. Mix deliming powder/solution according to package directions.
2. Remove the nozzle from the wand. Place a nylon stocking over the
wand assembly to collect debris, then place the wand assembly into
the float tank.
3. Turn the switch to the "Pump" position. Water will circulate throughout
the system and back into the float tank. Allow circulation to continue
for 2-4 hours.
4. Turn the switch to the "Off" position. Drain and clean the float tank.
Remove nylon stocking and clean wand assembly.
5. Flush the entire system with clean, fresh water, then replace nozzle
into wand assembly.
6. Dispose of deliming solution according to local, state and national
regulations.
TEST VOLTAGE & AMP DRAW: Use a volt meter and amp meter to test the
machine for correct voltage and amperage. If you do not have these instru-
ments or do not know how to use them, this procedure should be performed by
an authorized service technician.