10 | www.mhpgrills.com
CONNECTING THE GAS SUPPLY LINE (OC BASE)
STEP 5A-OC
CONNECT THE GAS LINE (FOR LP GAS INSTALLATIONS)
•
The LP Hose and Regulator are factory-installed onto
your grill head's LP Valve
•
Make sure your gas line runs through the hose
retaining notch opening and continues under
the heat shield as shown in the picture.
•
Attach the LP Regulator to your propane tank
and securely hand tighten the coupling nut to
the cylinder valve.
•
Before using your grill check for any gas leaks with
a soap and water solution before using your grill.
CONNECT THE GAS LINE (FOR NATURAL GAS INSTALLATIONS)
•
Attach the swivel connector end of the ASCPL1 hose
to the gas valve located under the control panel.
•
Make sure your gas line runs through the hose
retaining notch opening and continues under the
shelf as shown.
•
The socket (quick disconnect) end of the ASCPL1
hose attaches to your gas supply line at your gas
supply line's shut-off valve. Depending on the size of
your gas line you may need a reducer (not supplied
by MHP) to connect your gas line to the quick
disconnect socket (3/8" male pipe thread).
•
Tighten all gas connections securely. The use
of two wrenches is recommended—one wrench
is used to hold fitting while the other is used
to tighten.
•
Before using your grill check for any gas leaks with
a soap and water solution before using your grill.
INCLUDED WITH NATURAL GAS BASES
ASCPL1
12' NATURAL GAS HOSE
(QUICK DISCONNECT)
The swivel connector connects
to the grill's gas valve
The Quick Disconnct
Socket connects to your
gas supply line
The gas supply line must be regulated (in the case of natural gas that means it should be connected after your
gas meter and regulator) and you must have an easily accessible main shut-off valve to your grill’s gas
supply. Grills are designed to operate on a pressure of 7" w.c. in. for Natural or 11" w.c. in for Propane at the
grill valve connection.
When installing a new gas line, it is recommended that you
contact a plumber, heating contractor or licensed gas fitter to
install your new gas line to meet local building code. Be certain
there are no combustible materials closer than 18" away (above,
behind, left or right) from your assembled grill.
TOOLS NEEDED
3/4" OPEN END
ADJUSTABLE
WRENCH
HEAT SHIELD
GAS HOSE
GAS VALVE
SWIVEL
CONNECTOR
HOSE RETAINING
NOTCH OPENING
GAS SUPPLY
LINE
GAS FLOW
SOCKET PLUG
SWIVEL CONNECTOR
HOSE RETAINING
NOTCH OPENING
HEAT SHIELD
QCC-1 Cylinder Valve
Regulator
Coupling Nut
Turn clockwise to connect
Bleed Off Valve
Dust Cover
Pressure
Relief Valve