Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx
Page 15 of 17
7.4.
Changing lamps
How to replace a lamp:
1.
Open the flash cure by removing the two black caps and unscrewing the M4 bolts and cap
retainers on each side of the lid.
2.
Lift the lid and locate in the hole in the lid. Support the lid with the rod that can be found in
the front of the dryer. Note which cables are attached to the lamp to be changed, loosen the
bolts that secure the wires into the ceramics on either end of the lamp. pull the bolts out of
the ceramic and leave the cables loose.
3.
Remove the lamp from underneath the unit by loosening the wing nuts at either end of the
lamp. Hold it by the ceramics and ease it out of the lamp holders, now remove it from the
dryer.
4.
The lamps are installed in the dryer with tension springs at either end. Make sure that the
replacement lamps are installed in the right orientation.
5.
To install the replacement lamp, gently ease it into the holders. Guide the cables from either
end of the lamp through the reflector. Tighten the wing nuts until the lamp is secure but take
care not to over tighten them.
6.
Place each cable end in the lamp ceramics. Secure them by tightening the screw holding
them into each ceramic.
7.
After any accidental skin contact with the glas or quartz lamp surface the lamp has to be
degreased. To do this, gently clean the lamp with the provided cleaning cloth or other soft
cloth moistened with Denatured Alcohol or Methylated Spirits.
8.
Make sure that the ceramic ends of the lamp do not touch the housing and that the carbon
element is horizontal.
9.
Close the lid by the support rod and carefully lowering the lid. Secure the lid by re-inserting
the cap retainers, M4 bolts and black caps.
10.
Reattach the power cable and turn the unit on.
Safety precautions:
Unplug all mains power to the flash cure dryer.
If the flash cure was recently in operation ensure the unit has cooled down
before attempting to change the lamps.
The lamps are made of quartz glass and are therefore fragile –handle with
care and avoid contact with the glass.
Tools required: Slot screwdriver & crosshead screwdriver
If the lamp is thought to have failed under guarantee conditions, it should be
returned in appropriate packaging to MHM or other appointed dealer for
assessment.