Electrical requirements
The MHM Flash Cure must be connected to a suitable power supply. The permissible voltage can
be read on the type plate. An incorrect voltage will damage the device and result in loss of warranty.
The voltage will be either:
3x 400 V
=>
3 Phase + N + PE
or
3x 210 V
=>
3 Phase + PE
The frequency must be 50 Hz or 60 Hz. The values for voltage and frequency must be within ±5 %.
5.3.
Start signal
The MHM flash cure may be connected to the screen printing machine with the cable supplied or to
a footswitch, micro-switch, photocell or proximity switches, if so specified, via the connection
socket on the rear of the machine.
5.4.
Height adjustment
Using the screws in the brackets on the side of the Flash Cure the height can be adjusted. As an
initial setting a distance of 35-40 mm (1½ - 2ins) between the pallet and the lamps is recommended.
When connecting to 3x 400 V the NEUTRAL MUST be connected.
When connecting to 3x 210 V the NEUTRAL is NOT connected.