background image

Single Person

Electronic Digital Pulse-Demand 

Aviation Oxygen Delivery System

 MH EDS O

2

D

1

H

Aviation Oxygen Systems

M

MOUNTAIN HIGH

Equipment & Supply Company

INSTRUCTION MANUAL

4 mm

 Red 

inlet 

connects to the 

regulator

Power ON/OFF

 and 

Mode Control 

Switch

(with read-out window)

6 mm 

Blue 

outlets 

connect to cannula 

or face mask

Static ports, 

DO NOT 

COVER

800-468-8185 • 541-923-4100 • Fax: 541-923-4141 • www.MHoxygen.com • 2244 SE Airport Way, Suite 100 Redmond OR 97756-7537

 

Patent # 6,220,244

Other Patents Pending

CONTENTS

INTRODUCTION 

FEATURES 

BASIC SAFETY 

GETTING STARTED 

MODE CONTROL SWITCH SETTINGS 

AND MODES OF OPERATION

INSERTING OR REMOVING

THE BATTERIES 

4

2

2

2

3

TROUBLE-SHOOTING 

WARRANTY 

SPECIFICATIONS

REMOVING THE TUBING 

STORING THE MH EDS-O2D1 

MOUNTING THE MH EDS-O2D1 

USING THE MH EDS-O2D1 WITH A

THIRD PARTY REGULATOR

ALARMS AND ALERTS

4

4

4

5

7

6

6

7

8

Thank  you  for  purchasing  the  MH  EDS  O2D1 

Pulse-Demand  Oxygen  Controller.   The  MH  EDS 
O2D1 is patented oxygen control technology that 

allows you and your co-pilot to fly with safety and 
comfort,  knowing  it  will  automatically  give  the 
oxygen required at the various altitudes.  

THE EDS O2D1 IS DESIGNED FOR EASY 

OPERATION, PLEASE CAREFULLY READ 

THIS INSTRUCTION MANUAL BEFORE USE.

5MD10-0001-01 rev 4/5/12

Содержание EDS O2D1

Страница 1: ...TURES BASIC SAFETY GETTING STARTED MODE CONTROL SWITCH SETTINGS AND MODES OF OPERATION INSERTING OR REMOVING THE BATTERIES 4 2 2 2 3 TROUBLE SHOOTING WARRANTY SPECIFICATIONS REMOVING THE TUBING STORIN...

Страница 2: ...it By automatically detecting your pressure altitude the MH EDS O2D1 can be set to start providing oxygen immediately or at a specified altitude and will automatically adjust the oxygen flow as your...

Страница 3: ...on the back of the MH EDS O2D1 unit install the 2 AA batteries supplied and replace the battery cover NOTE Batteries fit tightly handle with care See next page for detailed instructions 5 If you are...

Страница 4: ...S O2D1 You may mount the MH EDS O2D1 unit to a suitable place using the supplied piece of 3M DUAL LOCK tape Peel the protective backing off one of the rectangles to expose the adhesive and apply it to...

Страница 5: ...e F10 setting you will receive the effective flow rate of 5 000 10 000 15 000 ft The F modes are useful for people for whom the standard oxygen supply does not achieve the desired blood oxygen saturat...

Страница 6: ...imes with audio beeps once every four 4 seconds until unit detects a valid inhalation event Time before Apnea event is 30 35 seconds This typically occurs for the following reasons 1 The user has quit...

Страница 7: ...aratus SCUBA Self Contained Underwater Breathing Apparatus or any medical operations Before it is put to use it is the responsibility of any user who will use this device to become familiar with the o...

Страница 8: ...and removed during long term storage Nominal battery voltage 2 875 VDC 40 mv 2 25 ma Idle 100 ma Peak 50 ms max 3 25 ma Average Min start up voltage 2 5 VDC 40 mv Low battery cut out 2 0 VDC 40 mv Red...

Отзывы: