INTRODUCTION

The patented MH EDS-O2D1 is an aviation oxygen delivery device for one person. It is designed to deliver aviation oxygen in the 
most efficient, comfortable and convenient way possible.  With its user-selectable settings, apnea alarm and small size, the MH 
EDS-O2D1 is the most portable and flexible electronic digital oxygen delivery system in the world. 

By providing a measured pulse of oxygen every time you breathe in, the MH EDS-O2D1 automatically supplies the oxygen you need 
to stay alert and comfortable while flying. In contrast to constant flow systems that waste oxygen by supplying more than your 
body can use, the MH EDS-O2D1 provides a short pulse of oxygen as you inhale, ensuring that your oxygen is used most efficiently. 
Efficient oxygen delivery means you can fly further on a single oxygen refill or save space and weight with a smaller tank. It also 
makes it more feasible to enjoy the advantages of oxygen while flying below the altitudes where oxygen is mandated--that can 
mean fewer headaches, increased alertness, and feeling less exhausted when you reach your destination. Your actual oxygen usage 
will be determined by your breathing rate and physiological needs at altitude.

The programmability of the MH EDS-O2D1 means that, unlike constant-flow oxygen systems, you can “set it and forget it”. By 
automatically detecting your pressure altitude, the MH EDS-O2D1 can be set to start providing oxygen immediately or at a specified 
altitude and will automatically adjust the oxygen flow as your altitude changes. When you’re flying, don’t you have more important 
things to do than adjust your oxygen flow during altitude changes?

BASIC SAFETY

Pure oxygen is a highly oxidizing gas and can vigorously accelerate combustion.  It can provide a catalyst for spontaneous 
combustion resulting in personal injury or death if not used properly and with caution.  

 

•  Easy-to-use two-button control, small size and light weight

 

•  Automatically adjusts oxygen flow for altitude pressure density.

 

•  Provides reduced oxygen consumption through more efficient oxygen delivery than standard constant-flow systems

 

•  Push button control switch allows automatic altitude enable, Night and Day operations and high flow settings

 

•  Green/Yellow/Red LEDs indicate oxygen flow, alarm, and status
• Audible and visible apnea alarm informs user of kinked, pinched, or disconnected oxygen lines, obstructed cannula or mask

 

•  Reduced dry mouth and sinus discomfort compared to constant-flow oxygen systems

FEATURES

6 mm 

Blue 

outlet connects 

to cannula or face mask

4 Static ports, 

DO NOT 

COVER

4 mm

 Red 

inlet 

connects to the 

regulator

Power ON 

 

and 

+

 Mode 

Switch

Green/Amber/Red LED

 

indicator for User

 

Power OFF 

and 

-

 Mode 

Switch

 DO NOT use any type of oil or grease on any of the fittings, valves or cylinders.  

 DO NOT smoke while in use. 

 DO NOT operate near an open flame.

Содержание EDS O2D1

Страница 1: ...TURES BASIC SAFETY GETTING STARTED MODE CONTROL SWITCH SETTINGS AND MODES OF OPERATION INSERTING OR REMOVING THE BATTERIES 4 2 2 2 3 TROUBLE SHOOTING WARRANTY SPECIFICATIONS REMOVING THE TUBING STORIN...

Страница 2: ...it By automatically detecting your pressure altitude the MH EDS O2D1 can be set to start providing oxygen immediately or at a specified altitude and will automatically adjust the oxygen flow as your...

Страница 3: ...on the back of the MH EDS O2D1 unit install the 2 AA batteries supplied and replace the battery cover NOTE Batteries fit tightly handle with care See next page for detailed instructions 5 If you are...

Страница 4: ...S O2D1 You may mount the MH EDS O2D1 unit to a suitable place using the supplied piece of 3M DUAL LOCK tape Peel the protective backing off one of the rectangles to expose the adhesive and apply it to...

Страница 5: ...e F10 setting you will receive the effective flow rate of 5 000 10 000 15 000 ft The F modes are useful for people for whom the standard oxygen supply does not achieve the desired blood oxygen saturat...

Страница 6: ...imes with audio beeps once every four 4 seconds until unit detects a valid inhalation event Time before Apnea event is 30 35 seconds This typically occurs for the following reasons 1 The user has quit...

Страница 7: ...aratus SCUBA Self Contained Underwater Breathing Apparatus or any medical operations Before it is put to use it is the responsibility of any user who will use this device to become familiar with the o...

Страница 8: ...and removed during long term storage Nominal battery voltage 2 875 VDC 40 mv 2 25 ma Idle 100 ma Peak 50 ms max 3 25 ma Average Min start up voltage 2 5 VDC 40 mv Low battery cut out 2 0 VDC 40 mv Red...