Wall formwork
Mammut XT
90° corner – Outside corner
When forming corners by means
of single-sided tying (see page
XT-40), the M alignment rail is
not required for pouring heights
up to 350 cm and wall thick-
nesses up to 30 cm (Figures. 44.1
to 44.5).
Attention must be paid to the
number of M assembly locks
required and their exact position
at the outside corner (a) and at
the panel joints (b) and (c) in
accordance with the pouring
height (Figures. 44.2 to 44.5 and
Table. 44.6).
For the position of the M assem-
bly locks refer to Figures. 44.2
to 44.5.
Pouring height
(in cm)
Number of M assembly locks
(single-sided tying up to h =
350 cm and WT = 30 cm)
(a)
(b)
(c)
350
7
7
7
330
6
6
6
310
6
6
6
290
5
5
5
270
5
5
5
250
4
4
4
274.5
197
145
99
70
38
13
0
0
269
187
129
85
45
15
0
206.5
137
88
45
16.5
0
Fig. 44.1
Fig. 44.2 Up to a pouring height of 350 cm
Fig. 44.3 Up to a pouring height of 330 cm
Fig. 44.5 Up to a pouring height of 250 cm
Table 44.6
Fig. 44.4 Up to a pouring height of 290 cm
180.5
105.5
44.5
19
0
b
a
c
b
a
c
XT-44
Technical Instruction Manual / Status September 2018