72
S
CANNER AND
C
ABLE
T
ERMINATIONS
C
ABLE
C
ONNECTOR
C
ONFIGURATIONS
Aux Port Configuration Cable*,
MLPN
57-57008
x
-N-3
Pin
Function**
1
No Connect
2
Output from Scanner
3
Input to Scanner
4
No Connect
5 Ground
6-9
No Connect
9-Pin D-Type Connector
RS232 LSO/AUX Cable,
MLPN
57-57099
x
-3
Pin
Function
†
1 Signal
Ground
2
RS232 from Aux / Secondary Scanner
3
RS232 to Aux / Secondary Scanner
4
RTS from Aux / Secondary Scanner
5
CTS to Aux / Secondary Scanner
6-8
No Connect
9
+ 5VDC – Transformer / Direct
10 Shield
Ground
10-Position Modular Plug
* This configuration cable was designed to be used with the StratosS auxiliary connector only.
** All signals are referenced from the StratosS scanner.
†
All signals are referenced from the auxiliary / secondary scanner.
Specifications are subject to change without notice.