24
I
NSTALLATION
C
ABLE
I
NSTALLATION
(I
NTERFACE
S
PECIFIC
)
OCIA
The following steps describe how to properly install the cables for an OCIA Stratos
S
application. The scanner/Avery scale
must
then be configured to match the host’s OCIA parameters. Cable installation alone
does not
guarantee that the Stratos
S
will communicate properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide
(
MLPN
00-02407
x
) and the
MS2
xxx
Stratos Series Configuration Addendum (
MLPN
00-02034
x
).
1. Turn off the host system.
2. Plug the 10-pin RJ45 end of the OCIA interface cable (
MLPN
57-57016
x
-N-3) into the 10-pin socket labeled
Scanner Host
OCIA
on the bottom of the Stratos
S
. Refer to figure on page 25.
3. Connect the other end of the OCIA Interface cable (
MLPN
57-57016
x
-N-3) to the appropriate communication port on the
host device.
Before continuing verify that the OCIA cable pinouts match the host system’s and is connected to the appropriate
interface socket on the scanner. An incorrect cable connection can cause communication problems or potential
damage to the scanner and/or terminal.
Manufacturers Note:
Plugging the scanner into the serial port of the host device does not guarantee that scanned
information will appear at the host device. A software driver and correct configuration settings are also required for
proper communication to occur.
Steps 4 and 5 are for
dual cable
interfaces where the scale and the scanner connect to the host with their own separate
communication cables. Skip to step 6 for a
single cable
interface where the scale and scanner connect to the host with a
single cable.
4. Plug the dual interface cable (
MLPN
57-57000
x
-N-3) into the 10-pin socket labeled
Scale RS232 to Host
, on the bottom of
the Stratos
S
.
5. Connect the other end of the dual interface cable (
MLPN
57-57000
x
-N-3) to the appropriate communication port on the
host’s scale device.
6. Plug
the
optional
remote display cable (
MLPN
46-00248
x
or 46-00249
x
) into the 10-pin socket labeled
Scale to Display
on the bottom of the Stratos
S
.
7. Plug the external power supply (
MLPN
46-002
xx
) into the 3-pin Molex socket labeled,
DC Power
In
, on the bottom of the
Stratos
S
.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet
should be located near the equipment and be easily accessible.
Metrologic recommends using a switched AC outlet. The switch should be located on the operator’s side of the
checkout counter in close proximity to the Stratos
S
to facilitate calibration and service of the unit.
8. Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.
9. Turn on the host system.
Содержание StratosS MS2220
Страница 1: ...METROLOGIC INSTRUMENTS INC MS2220 StratosS Scanner Avery Scale Installation and User s Guide...
Страница 6: ...v...
Страница 14: ...8 BASE MODEL CHARACTERISTICS MS2220 Scanner Avery Scale Components Figure 7 MS2220 Components...
Страница 86: ......
Страница 87: ......
Страница 88: ...December 2006 Printed in the USA 0 0 0 2 0 3 5 C...