Diagnostic Indicator Display
There is a two-digit error code display located under horizontal output window near the Metrologic logo on the platter (see
figure below).
Figure 30. Error Code Display (Optional Product Roll Bar Shown)
The following is a list of possible error codes and their meanings. Some errors will require immediate scanner maintenance.
E
RROR
C
ODE
D
ESCRIPTION
01 Reserved
02
RAM ERROR – The scanner’s Random Access Memory (RAM) is tested as faulty. Return the unit for repair at an
authorized service center.
03
PROGRAM ERROR – The scanner’s software program is failing. Return the unit for repair.
04
INTERFACE ERROR – After power up and any application exit (e.g. MetroSet, etc.), the scanner checks the
interface hardware with that chosen in configuration. If they do not agree, an interface error exists. Correct this
problem by getting the proper hardware interface OR programming Stratos
S
configuration for the proper interface
hardware attached.
05
CONFIGURATION ERROR – The non-volatile configuration memory did not agree with the data last saved.
Default configuration data is then used and the scanner continues operating. This error is also accompanied by 3
beeps. This error will remain during operation as a reminder that this power cycle is scanning against a default-
generated configuration.
Содержание StratosS MS2220
Страница 1: ...METROLOGIC INSTRUMENTS INC MS2220 StratosS Scanner Avery Scale Installation and User s Guide...
Страница 6: ...v...
Страница 14: ...8 BASE MODEL CHARACTERISTICS MS2220 Scanner Avery Scale Components Figure 7 MS2220 Components...
Страница 86: ......
Страница 87: ......
Страница 88: ...December 2006 Printed in the USA 0 0 0 2 0 3 5 C...