17
I
NSTALLATION
C
ABLE
I
NSTALLATION
(I
NTERFACE
S
PECIFIC
)
RS232
The following steps describe how to properly install the cables for an RS232 Stratos
S
application. The scanner/Avery scale
must
then be configured to match the host’s RS232 parameters. Cable installation alone
does not
guarantee that the
Stratos
S
will communicate properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide
(
MLPN
00-02407
x
) and the
MS2
xxx
Stratos Series Configuration Addendum (
MLPN
00-02034
x
).
1. Turn off the host system.
2. Plug the 10-pin RJ45 end of the RS232 interface cable (
MLPN
57-57210
x
-N-3) into the 10-pin socket labeled
Scanner Host RS232
,
on the bottom of the Stratos
S
. Refer to figure
on page 18.
3. Connect the other end of the RS232 cable to the proper communication port on the host device.
Before continuing, verify that the RS232 interface cable is connected to the appropriate interface socket on the
scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner
and/or terminal.
Steps 4 and 5 are for
dual cable
interfaces where the scale and the scanner connect to the host with their own separate
communication cables. Skip to step 6 for a
single cable
interface where the scale and scanner connect to the host with a
single cable.
4. Plug the dual interface cable (
MLPN
57-57000
x
-N-3) into the 10-pin socket labeled,
Scale RS232 to Host
, on the bottom
of the Stratos
S
.
5. Connect the other end of the dual interface cable (
MLPN
57-57000
x
-N-3) to the appropriate communication port on the
host’s scale device.
6. Plug
the
optional
remote display cable (
MLPN
46-00248
x
or 46-00249
x
) into the 10-pin socket labeled,
Scale to Display
,
on the bottom of the Stratos
S
.
7. Plug the external power supply (
MLPN
46-002
xx
) into the 3-pin Molex socket labeled, DC
Power In
, on the bottom of the
Stratos
S
.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet
should be located near the equipment and be easily accessible.
Metrologic recommends using a switched AC outlet. The switch should be located on the operator’s side of the
checkout counter in close proximity to the Stratos
S
to facilitate calibration and service of the unit.
8. Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.
9. Turn on the host system.
10. Scan the recall
Recall Defaults
bar code.
The
Recall Defaults
bar code is located in the MetroSelect Configuration Guide, under
Need to Start Over
on page xi (
MLPN
00-02407
x).
Содержание StratosS MS2220
Страница 1: ...METROLOGIC INSTRUMENTS INC MS2220 StratosS Scanner Avery Scale Installation and User s Guide...
Страница 6: ...v...
Страница 14: ...8 BASE MODEL CHARACTERISTICS MS2220 Scanner Avery Scale Components Figure 7 MS2220 Components...
Страница 86: ......
Страница 87: ......
Страница 88: ...December 2006 Printed in the USA 0 0 0 2 0 3 5 C...