![Metrohm 799 GPT Titrino Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/metrohm/799-gpt-titrino/799-gpt-titrino_short-instructions-for-use_1779570031.webp)
3.4
Configuration, key <CONFIG>
799 GPT Titrino: Other functions
29
>prep.dosing elements
power ON prep:
report:
dos.element:
warn.interv.
dos.drive:
Preparation of titration burets.
Warning after power ON.
Report.
Selection of dosing unit.
Warning interval.
Selection of type of dosing unit.
ON,
OFF
ON,
OFF
internal D0
, external D1/D2
5...9999 min,
OFF
Dosimat
, Dosino
volume
DX
cycle
DX
dos.rate DX
fill rate DX
Parameters for the internal dosing unit
and for 685 Dosimat
:
Volume.
Number of cycles.
Dosing rate.
Filling rate.
0...
3.5
...99 999.99 mL
1...
2
...9
0.01...150 mL/min,
max.
0.01...150 mL/min,
max.
output:
len.dos.tub.
diam.dos.tub.
len.asp.tub.
diam.asp.tub.
dos.rate DX
fill rate DX
Parameters for the 700 Dosino
:
Location, where liquid is expelled.
Length of the dosing tube.
Diameter of the dosing tube.
Length of the aspiration tube.
Diameter of the aspiration tube.
Dosing rate.
Filling rate.
tip
, flask
1.0...
40.0
...999.9 cm
0.1...
2.0
...9.9 mm
1.0...
25.0
...999.9 cm
0.1...
2.0
...9.9 mm
0.01...150 mL/min,
max.
0.01...150 mL/min,
max.