THIS FLUE KIT HAS BEEN MANUFACTURED IN 
ACCORDANCE WITH AS/NZS 2918:2001.
TO ENSURE SAFETY THIS FLUE KIT MUST BE INSTALLED 
AS OUTLINED IN THESE INSTRUCTIONS. THE APPLIANCE 
TO WHICH IT IS CONNECTED MUST BE INSTALLED 
IN ACCORDANCE WITH ITS MANUFACTURERS 
SPECIFICATIONS AND AS/NZS 2918:2001.

•  These installation instructions are for the Metro Ultra Insert 

appliance only.

 WARNING! 

Important Information

•  Mixing flue system components from different sources or modifying 

the dimensional specification of components may result in hazardous 
conditions. Where such action is considered, the manufacturer 
should be consulted in the first Instance.

•  It is the responsibility of the installer to ensure that the installation 

of this flue kit complies with AS/NZS 2918:2001, the appliance 
manufacturers specifications for flue pipe installation and that the 
relevant building codes are adhered to.

•  Bends and extensions to the length of a flue system are permitted 

(AS/NZS 2918:2001 4.1)

 

CAUTION! 

Important Information

Ultra Insert Flue Kit Installation Instructions & Component Checklist

(F) 

(E) 

(D) 

(C) 

(A) 

(B) 

(G) 

Please read these instructions fully prior to installation of the Ultra Insert flue 
kit and familiarise yourself with all the various components illustrated left and 
listed below.

Note: Rivets, fire cement, chimney cap/flashing plate and masonry vent cover 
are not included as they are supplied by the installer/home owner. Pioneer 
manufacture a stainless steel masonry vent cover kit to complete installation.

Ultra Insert Flue Kit Components

(A)  1 x Stainless steel weather butterfly

(B)  1 x Stainless steel ECO Cowl top

(C)  1 x 420mm x 240mm diameter stainless steel ECO Cowl housing

(D)  1 x 480mm long stainless steel flue pipe extension with flashing cone

(E)  2 x 1200mm x 150mm diameter stainless steel flue pipe

(F)  1 x 600mm x 250mm diameter galvanised outer casing

(G)  1 x 1300mm x 150mm diameter stainless steel flue pipe (pre-fitted liner)

The Ultra Insert flue kit features a custom 1300mm length of 150mm diameter 
flue pipe (G) with a pre-fitted stainless steel flue liner.

This section of lined flue must be fitted as close as possible to the Ultra Insert 
firebox. If possible connect directly to the Ultra Insert flue spigot, but if it is 
necessary to use a telescopic offset, then the section of lined flue must fit 
directly above this component.  

This flue kit has been manufactured and complies with AS/NZS2918:2001. To 
ensure a safe and efficient installation, this flue kit must be installed as detailed 
below by either a registered installer, or someone competent in installing solid 
fuel appliances.

1.   Check the masonry chimney for structural soundness and make any 

repairs that are necessary.

Note: Most councils require the masonry chimney to be inspected prior to 
installation. The masonry chimney cavity must also be swept prior to installation.

2.   Once the fireplace insert has been installed correctly to the manufacturers 

instructions, look directly down the chimney to ensure the firebox flue 
spigot is in line with the masonry chimney. (A torch will be required). 

3.   If you cannot see the flue spigot, a flue pipe offset will be required. If so, 

install the flue pipe offset so the top of it can be clearly seen from the top of 
the masonry chimney.

Содержание Ultra Insert

Страница 1: ...quirements 9 Getting to know your Metro 10 Replacement parts accessories 11 Operating your Metro 11 Cleaning and maintenance 13 Troubleshooting 14 Metro warranty 15 Ultra Insert Wood Fire Wood Fire In...

Страница 2: ...lue pipe exposed A rear cavity vent is required Please see detail in Diagram 1 opposite with full cavity vent requirements and installation detailed on page 8 of this manual In New Zealand the Metro U...

Страница 3: ...lation instructions detailed on page 6 proceed and fit the flue with All JOINTS SEALED and riveted with a minimum of three stainless steel or monel rivets on each joint 7 With Pioneer fire cement appl...

Страница 4: ...or cabinet Ensure the fan rotates freely 4 Rotate the door handle fully anti clockwise before placement of the fascia The inner fascia slips snugly into the cabinet with the Top Rail of the fascia res...

Страница 5: ...s in its correct position in the top chamber of the firebox It should be resting on four support lugs two on each side of the firebox The baffle must be hard back against the rear wall of the firebox...

Страница 6: ...omponents A 1 x Stainless steel weather butterfly B 1 x Stainless steel ECO Cowl top C 1 x 420mm x 240mm diameter stainless steel ECO Cowl housing D 1 x 480mm long stainless steel flue pipe extension...

Страница 7: ...eather butterfly A so the angled sections are facing up With both arms and angled sections of the stainless steel weather butterfly A facing up fit it into the stainless steel ECO Cowl top B and secur...

Страница 8: ...nd bead off around the perimeter Fill the weather seal groove with silicon and embed the weather strip fully into the silicon to ensure weather tightness Chimney vent requirements 230mm Maximum height...

Страница 9: ...de of the door opening making the minimum floor protector width 825mm The insulated floor protector must project from behind the fascia the distance specified I in the table below Minimum projection i...

Страница 10: ...baffle plate promet extension white board on the baffle plate It is critical that the fire not be operated with cracked or broken door glass It is critical that the fire is operated with the fan switc...

Страница 11: ...easoned 12 months later Burning properly seasoned dry fuel will result in Less ash buildup Less emission into the environment Less creosote that can cause a host of issues Maintain a clean flue system...

Страница 12: ...latch After 2 minutes with the kindling well alight fully close the door Intermediate load with air control fully open Approximately 40 minutes after lighting once remaining fuel has formed hot coals...

Страница 13: ...epends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door and using a hearth shovel or similar empty the excess ash directly into a s...

Страница 14: ...We highly recommend the Metro ECO Cowl is fitted as this will increase the draw If you already have an ECO Cowl and smoke is still entering the room please add another 600mm length of flue pipe Downd...

Страница 15: ...the life span will be reduced If your Metro wood fire has been neglected by not being regularly maintained and serviced warranty may be declined It is critical the fire not be operated with over worn...

Страница 16: ......

Отзывы: