Troubleshooting your Metro wood fire

If your Metro is installed correctly, your fuel is dry and you operate your 
fire correctly, you will find it to be a pleasure to use. Metro’s many years of 
experience within the wood heating industry has shown that dissatisfaction 
is mainly due to:

•   unseasoned fuel
•   faulty installation
•   operational error
•   or a combination of the above 3 points.

Correct operation

Modern day wood fires need to be operated hard and fast, more so than 
low and lazy to ensure the firebox and flue pipe runs hot and efficiently. If 
the fire and flue pipe is up to temperature it will perform extremely well, the 
smoke will draw up the flue pipe with ease, and the fire will produce good 
amounts of heat.

If the fire is operated on low a lot of the time, the door glass will run black, 
the flue pipe will tend to block up more frequently and the fire will end 
up smoking into the room when reloading. It’s better to have a small fire 
running hard and fast, rather than a big fire running low and lazy.

The following may be of assistance if you are experiencing any problems 
with the operation of your Metro Fire.

Smoke enters the room when the Metro’s door is ajar 

(possible reasons and solutions)

Check flue pipe joins

If the flue pipe joins are not sealed correctly, the flue pipe will not draw as well 
as it should. The flue pipe join connecting into the flue spigot on top of the 
Metro is most critical, if this is not sealed correctly, smoke will enter the room 
when the door is ajar. To check this join is sealed correctly, run a match or 
lighter flame around the join. If the flame is sucked into the spigot then it is 
not sealed correctly. This check needs to be done when the fire is not going. 
Ensure you check the rear of the flue pipe/spigot join, as due to the seam in 
the flue pipe, this is the most common area for not being sealed correctly.

Ensure the fuel you are using is correctly seasoned

If you are burning unseasoned fuel (wet), the fire will cause nothing but 
problems. The Metro won’t deliver much heat, it will be lazy, smoke will 
enter the room when the door is ajar, and the door glass will run black. 
Unseasoned fuel is the main contributor to excessive creosote deposits 
which can be corrosive to your appliance and flue system.

Flue pipe length is too short

Add more flue pipe as the longer the flue system, the better the draw of 
the flue pipe. Please note, if you did not purchase the Metro ECO Flue 
System, you will not have the ECO Cowl which increases draw. We highly 
recommend the Metro ECO Cowl is fitted as this will increase the draw. If 
you already have an ECO Cowl and smoke is still entering the room, please 
add another 600mm length of flue pipe.

Downdraft/Turbulence blockage

If you have checked all of the previous factors and the fire is still smoking 
into the room, it’s possible there may be a down draft issue. Down draft is 
environmental and can be caused by many variables, and it is purely trial 
and error to ascertain the cause.

Air turbulence and/or negative air pressure influences around the flue 
termination can be caused by too close or overhanging trees or natural/
artificial ridges etc. Address these where possible or look to extend the flue 
above the roofline.

Other options may be:

•   ‘H’ Cowl, designed purely for downdraft issues, but if you have an ECO 

Cowl fitted as standard, you will also need to add another 600mm of 
flue pipe to compensate as the H Cowl is shorter in length

•   Directional Cowl, designed for high wind areas.

Air control setting

Ensure the air control setting is on high before opening the door to reload, 
as this increases the draw up the flue pipe. Open the door slowly.

If your Metro did not smoke, but its starting too and is getting worse:

The flue pipe is in need of a clean. It is recommended that the flue pipe be 
cleaned every season, however if you are burning the fire on low a lot, or are 
using unseasoned fuel, flue pipe cleans will be required more frequently.

Other issues you may experience

I can smell smoke in the room after a low burn cycle

The smell is creosote that will be seeping through the flue pipe join or 
out of the flue spigot onto an external surface, thus creating the smell 
in your room. The cause will be either unseasoned fuel, fuel mass too 
large, incorrect operation on low burn cycles or a combination. Creosote 
is very corrosive and excessive buildups will result in the flue pipe and 
potentially the flue spigot and upper burn chamber failing. The formation 
of excessive creosote is not an appliance issue, it is a fuel and operational 
issue. Failure of flue pipe or firebox due to creosote build up is not covered 
under warranty as excessive creosote build up is only possible from either 
unseasoned fuel or incorrect operation.

The Metro won’t turn down as much as it did

The door itself may need readjusting, the hinge and latch is slotted and 
allows for movement. Loosening the hinge and moving it back a few mm will 
make the door seal tighter and stop air leaking into the fire. The door and 
glass seals may be in need of replacing, which is generally required every 
3-4 years.

Familiarise yourself with the instructions on page 13 before proceeding with 
this maintenance.

Содержание Ultra Insert

Страница 1: ...quirements 9 Getting to know your Metro 10 Replacement parts accessories 11 Operating your Metro 11 Cleaning and maintenance 13 Troubleshooting 14 Metro warranty 15 Ultra Insert Wood Fire Wood Fire In...

Страница 2: ...lue pipe exposed A rear cavity vent is required Please see detail in Diagram 1 opposite with full cavity vent requirements and installation detailed on page 8 of this manual In New Zealand the Metro U...

Страница 3: ...lation instructions detailed on page 6 proceed and fit the flue with All JOINTS SEALED and riveted with a minimum of three stainless steel or monel rivets on each joint 7 With Pioneer fire cement appl...

Страница 4: ...or cabinet Ensure the fan rotates freely 4 Rotate the door handle fully anti clockwise before placement of the fascia The inner fascia slips snugly into the cabinet with the Top Rail of the fascia res...

Страница 5: ...s in its correct position in the top chamber of the firebox It should be resting on four support lugs two on each side of the firebox The baffle must be hard back against the rear wall of the firebox...

Страница 6: ...omponents A 1 x Stainless steel weather butterfly B 1 x Stainless steel ECO Cowl top C 1 x 420mm x 240mm diameter stainless steel ECO Cowl housing D 1 x 480mm long stainless steel flue pipe extension...

Страница 7: ...eather butterfly A so the angled sections are facing up With both arms and angled sections of the stainless steel weather butterfly A facing up fit it into the stainless steel ECO Cowl top B and secur...

Страница 8: ...nd bead off around the perimeter Fill the weather seal groove with silicon and embed the weather strip fully into the silicon to ensure weather tightness Chimney vent requirements 230mm Maximum height...

Страница 9: ...de of the door opening making the minimum floor protector width 825mm The insulated floor protector must project from behind the fascia the distance specified I in the table below Minimum projection i...

Страница 10: ...baffle plate promet extension white board on the baffle plate It is critical that the fire not be operated with cracked or broken door glass It is critical that the fire is operated with the fan switc...

Страница 11: ...easoned 12 months later Burning properly seasoned dry fuel will result in Less ash buildup Less emission into the environment Less creosote that can cause a host of issues Maintain a clean flue system...

Страница 12: ...latch After 2 minutes with the kindling well alight fully close the door Intermediate load with air control fully open Approximately 40 minutes after lighting once remaining fuel has formed hot coals...

Страница 13: ...epends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door and using a hearth shovel or similar empty the excess ash directly into a s...

Страница 14: ...We highly recommend the Metro ECO Cowl is fitted as this will increase the draw If you already have an ECO Cowl and smoke is still entering the room please add another 600mm length of flue pipe Downd...

Страница 15: ...the life span will be reduced If your Metro wood fire has been neglected by not being regularly maintained and serviced warranty may be declined It is critical the fire not be operated with over worn...

Страница 16: ......

Отзывы: