INSTALLING & SETTING-UP
17
76-02-011F
5 INSTALLING & SETTING-UP
This chapter describes how to set up the FM4900 ready for use. It covers the initial
connections, powering on the unit, and how to access the software that controls the
operating parameters.
Setting and changing these parameters is covered in Section 6, Configuring FM4900.
Safety Notice:
Ports that are identified as SELV in this manual should only be connected to
SELV ports on other equipment in accordance with EN 60950 clause 2.3.
5. 1 Connections
Step 1: Mounting
The FM4900 is housed in a convenient 1U table top enclosure. The unit may also be
installed in a 19" rack using the 1U rack mounting brackets supplied.
Step 2: DTE
Connect the FM4900 to the DTE, using the 50-way AMP connector labelled DTE on the rear
panel of the unit. The DSU should ideally be placed close to the DTE, with no more than 2m
of cable connecting the two.
Step 3: WAN
Connect the WAN by means of the two BNC bayonet connectors on the rear panel of the
unit.
Note:
Before connecting the network port, make sure that you have read the information
under Network connection in section 4.8.
Step 4: Terminal
Connect the management terminal (Teletype or VDU) using the 25-way D- type connector
labelled
TERMINAL
on the rear panel of the unit.
Step 5: Alarm Extension
If you wish to use an external alarm device, connect this to the alarm extension port.
Step 6: SNMP Management Port
If you have the LM1100 SNMP Enabler option and wish to use it, connect the LAN to the port
labelled MAN PORT using an RJ45 connector.
Step 7: Power Supply
Finally, connect the mains power lead (or DC power cable) and re-check all connections for
security. See section 2.4 for connection details for the optional -48V DC power supply. Turn
on the terminal and external alarm device if used, then turn on the power supply.
Warning:
Do not connect the FM4900 to excessive voltages. Read the safety information
before continuing.