INTRODUCING THE FM4900
76-02-011F
10
4. 2 Rear panel
Figure 4. 3 FM4900 Rear panel
4. 3 Power Supply
The FM4900 is powered by a mains power supply with an input voltage range 100-250 VAC
/ 50-400 Hz. The maximum input current is 0
⋅
2A rms. at 240V.
An alternative -48VDC powered unit is available. The input voltage and current ranges are -
minus 36 to minus 72 volts DC. A Buccaneer type socket is fitted to the rear panel, and a
plug is provided with the unit for the customer’s own wiring. The connections are labelled on
the rear panel of the unit.
On some units, an additional Ground stud may be located on the rear panel to permit a
separate Ground connection to be made.
Figure 4. 4 -48VDC connections
T
Note:
The FM4900 must be connected to safety earth for correct operation.
Pin no
Connection
1
-48VDC
2
Ground
3
0VDC