Outdoor 1200 Braai specifications 

(Minimum clearances shown in mm)

Installation clearances

The Outdoor 1200 is for outdoor use only and cannot be installed inside 
the home. Confirm with the local building authority or Metro stockist for the 
outdoor fire regulations in your local area.

Installation clearances in the table below are to a combustible wall or fence 
to a maximum height of 2400mm. All clearances are measured from the 
following reference points as illustrated in the diagrams below:

• 

The nearest combustible wall or surface (A, B, C, D, E)   

• 

The firebox / heatshield outermost point (A, B, C, D)

• 

The edge of the ash floor protectors non-combustible surface (C)

When applying the minimum side clearance (B) to your installation, the 
adjacent combustible wall or surface must not project forward of the Outdoor 
1200 firebox opening.

Installation

Do not install the Outdoor 1200 under a roof, verandah or the eaves of your 
home. A minimum clearance radius of 2m is required from the top of the 
flue cowling to any surrounding combustible object. 

The Outdoor 1200 must be installed on a non combustible plinth or bench 
and secured by fixing points located in the base of the firebox or by locking 
the braked castors on the trolley once the fire is in place. 

The Outdoor 1200 is fitted with a stainless steel door to protect the fire’s 
interior when the appliance is not in operation. During operation, the door is 
easily removed and put aside. The trolley base features built-in door rails to 
slide the door (face up)beneath the trolley for convenient, practical storage.

If you are constructing your own base we recommend a minimum base 
height of 735mm with a minimum depth of 530mm to allow the door to 
hang down below the fire during operation. The front of the base must finish 
flush with the front of the Outdoor 1200 to allow the door to hang correctly.  
Alternatively, we recommend a base opening dimension of 1300mm wide 
with a depth of 750mm to allow you to fit door rails to the inside of the base 
to slide the door beneath the fire.

External structures and the proximity of other buildings will differ for every 
installation so before lighting your appliance, make sure your Outdoor 
1200 is located away from buildings, structures, vegetation, and any other 
combustible objects by the minimum clearances detailed.

1700mm

80

0mm

1280mm

530

m

m

Minimum installation clearances (mm)

Dimensions

A

B

C

D

E

OUTDOOR 1200

TROLLEY BASE

WIDTH

DEPTH

HEIGHT

WIDTH

DEPTH

HEIGHT

250

500

500

250

1880

1280

530

1300

1700

800

735

Specifications were correct at the time of printing but may alter and those detailed within should be used only as a guide. Full assembly and installation instructions are detailed in the Outdoor Installation 

manuals available at metrofires.co.nz. If in doubt, please consult your local Metro Fires stockist or visit metrofires.co.nz.

Содержание outdoor 1200 Braai

Страница 1: ...or requirements 7 Ember tool assembly 7 Important operation information 8 Operating your Outdoor 1200 Braai 9 Cleaning and maintenance 10 Outdoor by Metro warranty 11 Outdoor by Metro accessories 12 Outdoor 1200 Braai Installation Owner s Operation Manual 05 21 PIONEER MANUFACTURING LTD 19 Oropuriri Road New Plymouth 4312 info metrofires co nz www metrofires co nz ...

Страница 2: ...s Any modification of the appliance that has not been approved in writing by the manufacturer is considered to be in breach of the warranty DO NOT use your Outdoor 1200 Braai for cooking purposes during the initial 2 3 burning cycles or after spraying with high temperature paint during regular maintenance WARNING Important Information Mixing of appliance or flue system components from different so...

Страница 3: ...n combustible and should extend a minimum of 700mm out from the front face of the firebox Floor protectors must be constructed of non combustible material and must be a minimum width of 1880mm See page 7 for full details Assembly of your Outdoor Braai Your Outdoor 1200 Braai is packed in a single heavy duty carton and tek screwed to a wooden pallet Having removed the packaging and located this man...

Страница 4: ...making sure the fire is fastened down securely These fixings are included if you have purchased the trolley Unscrew the gather from the freight pallet The gather is fixed to the pallet with 2x 8mm tek screws in opposing corners Using 2 4 people lift the gather into position on top of the firebox ensuring the 4 x attachment holes are lined up with the holes in the top of the firebox Unwrap the 2x s...

Страница 5: ...er and the vertical discharge cowl 2 Place the 350mm flue pipe inside the 400mm outer liner Ensure the safe edge and the swage on the 350mm flue are at the same end Attach the cowl to the top of the liner Using a drill and suitable drill bit drill 2 x holes per tab in the liner and attach using 3 2mm stainless steel rivets supplied 3 When lifting the flue system vertically the 350mm will drop down...

Страница 6: ...e fire s interior when the appliance is not in operation During operation the door is easily removed and put aside The trolley base features built in door rails to slide the door face up beneath the trolley for convenient practical storage If you are constructing your own base we recommend a minimum base height of 735mm with a minimum depth of 530mm to allow the door to hang down below the fire du...

Страница 7: ... be a minimum width of 1880mm A suitable floor protector for an Outdoor 1200 Braai is therefore any non combustible material which could include Cement based tiles or similar with grouted joints fixed directly to a hard base over combustible flooring A sheet of panel steel etc laid directly onto any combustible floor Once installed all minimum clearances and floor protection dimensions must be adh...

Страница 8: ...to operate efficiently firewood that contains a high moisture content will result in flue pipe blockages reduce heat output and create other issues Note Once split Softwood usually takes 12 months to season Hardwood can take up to 24 months to season Wood must be stored in a location that enables air circulation Unseasoned wood stored in a closed woodshed without air circulation will still be unse...

Страница 9: ... the ember pot To help start the hardwood place 2 3 pieces of pine cut into a similar size and place in the ember maker with the hardwood 2 Using a few fire lighters placed onto a piece of fuel slide this into the burn tray under the ember maker and light Within 10 minutes the fuel in the ember pot should be entirely ablaze 3 After 30 minutes embers will start falling through the bottom of the emb...

Страница 10: ...ally If a wood fire is not regularly maintained and serviced the life span will be reduced If your Outdoor 1200 Braai has been neglected by not being regularly maintained and serviced with authorised Metro parts replaced as required your warranty may be declined Sacrifical wear parts should be replaced as soon as they show signs of wear Operating your Outdoor 1200 Braai with worn or broken parts m...

Страница 11: ...must be regularly maintained and we recommended it is also serviced annually Proof of servicing may be required If a wood fire is not regularly maintained and serviced the life span will be reduced If your Outdoor 1200 Braai has been neglected by not being regularly maintained and serviced a warranty claim may be declined It is critical the fire not be operated with over worn faulty or missing par...

Страница 12: ...s and more For further details ask your Metro stockist for a copy of the Outdoor by Metro brochure or visit metrofires co nz to download a copy Outdoor 1200 accessories Stainless steel side racks INCLUDED Cast iron cooking plate INCLUDED Stainless steel cooking grills small INCLUDED Pizza cutter Stainless steel grill baskets INCLUDED Outdoor fire mitts INCLUDED Wooden pizza paddle Stainless steel ...

Отзывы: