Outdoor 1200 Braai specifications
(Minimum clearances shown in mm)
Installation clearances
The Outdoor 1200 is for outdoor use only and cannot be installed inside
the home. Confirm with the local building authority or Metro stockist for the
outdoor fire regulations in your local area.
Installation clearances in the table below are to a combustible wall or fence
to a maximum height of 2400mm. All clearances are measured from the
following reference points as illustrated in the diagrams below:
•
The nearest combustible wall or surface (A, B, C, D, E)
•
The firebox / heatshield outermost point (A, B, C, D)
•
The edge of the ash floor protectors non-combustible surface (C)
When applying the minimum side clearance (B) to your installation, the
adjacent combustible wall or surface must not project forward of the Outdoor
1200 firebox opening.
Installation
Do not install the Outdoor 1200 under a roof, verandah or the eaves of your
home. A minimum clearance radius of 2m is required from the top of the
flue cowling to any surrounding combustible object.
The Outdoor 1200 must be installed on a non combustible plinth or bench
and secured by fixing points located in the base of the firebox or by locking
the braked castors on the trolley once the fire is in place.
The Outdoor 1200 is fitted with a stainless steel door to protect the fire’s
interior when the appliance is not in operation. During operation, the door is
easily removed and put aside. The trolley base features built-in door rails to
slide the door (face up)beneath the trolley for convenient, practical storage.
If you are constructing your own base we recommend a minimum base
height of 735mm with a minimum depth of 530mm to allow the door to
hang down below the fire during operation. The front of the base must finish
flush with the front of the Outdoor 1200 to allow the door to hang correctly.
Alternatively, we recommend a base opening dimension of 1300mm wide
with a depth of 750mm to allow you to fit door rails to the inside of the base
to slide the door beneath the fire.
External structures and the proximity of other buildings will differ for every
installation so before lighting your appliance, make sure your Outdoor
1200 is located away from buildings, structures, vegetation, and any other
combustible objects by the minimum clearances detailed.
1700mm
80
0mm
1280mm
530
m
m
Minimum installation clearances (mm)
Dimensions
A
B
C
D
E
OUTDOOR 1200
TROLLEY BASE
WIDTH
DEPTH
HEIGHT
WIDTH
DEPTH
HEIGHT
250
500
500
250
1880
1280
530
1300
1700
800
735
Specifications were correct at the time of printing but may alter and those detailed within should be used only as a guide. Full assembly and installation instructions are detailed in the Outdoor Installation