The Outdoor 1200 Braai has been tested with the Outdoor 1200 flue system 
only. For the Outdoor 1200 Braai to be installed with the minimal clearances 
as the clearance table on page 6 states, only the Outdoor 1200 flue system 
can be used. All other flue systems will invalidate the installation clearances.

The flue system is for a freestanding appliance only.

Outdoor 1200 Flue Kit Components 

(A)   1 x stainless steel vertical discharge Outdoor cowl housing

(B)   1 x 400mm diameter x 1200mm stainless steel liner

(C)   1 x 350mm diameter x 1200mm stainless steel flue pipe

(+)   4 x M8x16 stainless steel dome head sockets 

4 x 8mm flat washers 
8 x 3.2mm stainless steel rivets

Flue installation

Having positioned your Outdoor 1200 Braai in the desired location, check to 
ensure the fire and floor protector (if applicable) have adequate clearances 
and projections, and that the flue system is clear of all combustible surfaces 
and materials as detailed on page 6.

We recommend that you use nitrile gloves to assemble the flue system. 
This is due to hand and finger marking showing on the flue after burning 
the fire. It will also pay to clean the flue system after assembly using a 
microfibre cloth and methylated spirits (ensure there is no methylated spirits 
contamination to the painted surfaces of the appliance).

1.  Unbox the 350mm flue with 4 x spacer tabs, 400mm outer liner 

(support liner) and the vertical discharge cowl.

2.  Place the 350mm flue pipe inside the 400mm outer liner. Ensure the 

safe edge and the swage on the 350mm flue are at the same end. 
Attach the cowl to the top of the liner. Using a drill and suitable drill 
bit, drill 2 x holes per tab in the liner and attach using 3.2mm stainless 
steel rivets supplied.

3.  When lifting the flue system vertically the 350mm will drop down (but 

not out) so that approximately 75mm protrudes making it easier to line 
up with the 350mm spigot. Once you have the 350mm flue placed into 
the spigot lower the 400mm liner down over the top of the 4 x threaded 
tabs. Line up the fixing holes and attach using the 4 x M8x16mm 
stainless dome headed sockets and flat washers and tighten.

Outdoor 1200 Braai flue kit installation

• WE STRONGLY RECOMMEND USING A QUALIFIED 

INSTALLER TO ASSEMBLE THE FIRE AND ERECT THE 
FLUE SYSTEM ON YOUR OUTDOOR 1200 BRAAI

•  Any modification to this flue system that has not been approved 

in writing by the manufacturer is considered to be in breach of all 
safety clearance approvals granted.

•  Please note the edges of the flue system are very sharp.

 WARNING! 

Important Information

•  Mixing of appliance or flue-system components from different 

sources or modifying the dimensional specification or components 
may result in hazardous conditions. Where such action is considered, 
the manufacturer should be consulted in the first instance

•  Prior to installing the assembled flue pipe, take careful note to 

ensure there are no overhead power lines in close proximity.

 

CAUTION! 

Important Information

A

B

C

Содержание outdoor 1200 Braai

Страница 1: ...or requirements 7 Ember tool assembly 7 Important operation information 8 Operating your Outdoor 1200 Braai 9 Cleaning and maintenance 10 Outdoor by Metro warranty 11 Outdoor by Metro accessories 12 Outdoor 1200 Braai Installation Owner s Operation Manual 05 21 PIONEER MANUFACTURING LTD 19 Oropuriri Road New Plymouth 4312 info metrofires co nz www metrofires co nz ...

Страница 2: ...s Any modification of the appliance that has not been approved in writing by the manufacturer is considered to be in breach of the warranty DO NOT use your Outdoor 1200 Braai for cooking purposes during the initial 2 3 burning cycles or after spraying with high temperature paint during regular maintenance WARNING Important Information Mixing of appliance or flue system components from different so...

Страница 3: ...n combustible and should extend a minimum of 700mm out from the front face of the firebox Floor protectors must be constructed of non combustible material and must be a minimum width of 1880mm See page 7 for full details Assembly of your Outdoor Braai Your Outdoor 1200 Braai is packed in a single heavy duty carton and tek screwed to a wooden pallet Having removed the packaging and located this man...

Страница 4: ...making sure the fire is fastened down securely These fixings are included if you have purchased the trolley Unscrew the gather from the freight pallet The gather is fixed to the pallet with 2x 8mm tek screws in opposing corners Using 2 4 people lift the gather into position on top of the firebox ensuring the 4 x attachment holes are lined up with the holes in the top of the firebox Unwrap the 2x s...

Страница 5: ...er and the vertical discharge cowl 2 Place the 350mm flue pipe inside the 400mm outer liner Ensure the safe edge and the swage on the 350mm flue are at the same end Attach the cowl to the top of the liner Using a drill and suitable drill bit drill 2 x holes per tab in the liner and attach using 3 2mm stainless steel rivets supplied 3 When lifting the flue system vertically the 350mm will drop down...

Страница 6: ...e fire s interior when the appliance is not in operation During operation the door is easily removed and put aside The trolley base features built in door rails to slide the door face up beneath the trolley for convenient practical storage If you are constructing your own base we recommend a minimum base height of 735mm with a minimum depth of 530mm to allow the door to hang down below the fire du...

Страница 7: ... be a minimum width of 1880mm A suitable floor protector for an Outdoor 1200 Braai is therefore any non combustible material which could include Cement based tiles or similar with grouted joints fixed directly to a hard base over combustible flooring A sheet of panel steel etc laid directly onto any combustible floor Once installed all minimum clearances and floor protection dimensions must be adh...

Страница 8: ...to operate efficiently firewood that contains a high moisture content will result in flue pipe blockages reduce heat output and create other issues Note Once split Softwood usually takes 12 months to season Hardwood can take up to 24 months to season Wood must be stored in a location that enables air circulation Unseasoned wood stored in a closed woodshed without air circulation will still be unse...

Страница 9: ... the ember pot To help start the hardwood place 2 3 pieces of pine cut into a similar size and place in the ember maker with the hardwood 2 Using a few fire lighters placed onto a piece of fuel slide this into the burn tray under the ember maker and light Within 10 minutes the fuel in the ember pot should be entirely ablaze 3 After 30 minutes embers will start falling through the bottom of the emb...

Страница 10: ...ally If a wood fire is not regularly maintained and serviced the life span will be reduced If your Outdoor 1200 Braai has been neglected by not being regularly maintained and serviced with authorised Metro parts replaced as required your warranty may be declined Sacrifical wear parts should be replaced as soon as they show signs of wear Operating your Outdoor 1200 Braai with worn or broken parts m...

Страница 11: ...must be regularly maintained and we recommended it is also serviced annually Proof of servicing may be required If a wood fire is not regularly maintained and serviced the life span will be reduced If your Outdoor 1200 Braai has been neglected by not being regularly maintained and serviced a warranty claim may be declined It is critical the fire not be operated with over worn faulty or missing par...

Страница 12: ...s and more For further details ask your Metro stockist for a copy of the Outdoor by Metro brochure or visit metrofires co nz to download a copy Outdoor 1200 accessories Stainless steel side racks INCLUDED Cast iron cooking plate INCLUDED Stainless steel cooking grills small INCLUDED Pizza cutter Stainless steel grill baskets INCLUDED Outdoor fire mitts INCLUDED Wooden pizza paddle Stainless steel ...

Отзывы: