3
Installation location
Evaluate the location for your outdoor fire, surroundings, and neighbouring
properties. The land’s topography will have a bearing on how the wind and
overall environment may affect the fire and flue system.
Consider surrounding trees, neighbouring property boundaries, buildings, or
wooden fences. Locate the Outdoor 1200 Braai at a safe distance from any
combustible objects, trees, shrubs, wood storage piles, buildings, property
boundaries, or wooden fences. (See clearance detail on page 6).
Elevation of fire
Decide the height of the fire installation above ground level. We recommend
that your Outdoor 1200 Braai be installed 700-800mm above ground level
to provide easy access and convenience during operation.
For a custom base/plinth design, we recommend a minimum base
thickness of 125mm, designed and constructed with sufficient supports to
bear the total weight of fire and the flue kit.
Alternatively, Metro manufacture a dedicated trolley base for this purpose.
Floor protector
Floor protector requirements depend upon the elevation of the fire above
ground level and the substrate beneath the installation.
- For an elevated installation of 500mm or more above ground level,
only an Ash floor protector is required and must extend a minimum of
500mm out from the front face of the firebox.
- We recommend for installation heights below 500mm, the floor must
be non-combustible and should extend a minimum of 700mm out
from the front face of the firebox.
- Floor protectors must be constructed of non-combustible material and
must be a minimum width of 1880mm. See page 7 for full details.
Assembly of your Outdoor Braai
Your Outdoor 1200 Braai is packed in a single heavy-duty carton, and tek
screwed to a wooden pallet. Having removed the packaging and located this
manual, please familiarise yourself with the illustration opposite and images
on pages 4 & 5, and proceed as follows.
Your Outdoor 1200 Braai is supplied partially assembled.
Packed inside the firebox you will find the following:
•
2x stainless steel side panels
•
2x boxes of bricks (4x bricks)
•
2x stainless steel side racks
•
1x ember tool
•
1x pair of Metro fire mitts
•
2x stainless steel grill racks
•
1x stainless steel ember maker
•
2x grill baskets
•
1x cast iron cooking plate
•
1x bolt bag of fastenings
You will also need the following tools (not included)
•
10mm ring spanner
•
8mm and 10mm socket ratchet
•
Electric drill and 3.2mm drill bit to suit rivet
•
4mm and 5mm Hex key
•
Pop rivet gun
Custom base installation
The Outdoor 1200 is designed for
installation onto a non-combustible
plinth or benchtop to your desired
design or can be installed onto the
Outdoor trolley base opposite.
Trolley base installation
The aluminium and stainless steel
trolley provides storage for your
firewood and features built-in rails
to slide the door neatly underneath
the Outdoor 1200 during operation.
Outdoor 1200 Braai Installation
Gather
Side panel
Door
Side rack
Firebrick x4
Ember maker
Wood stops
Burn tray