FLEXLINE ELECTRONIC PIN LOCK —
INSTRUCTIONS FOR USE
6
www.metro.com
L01-655
REV 01/20
Delete User From Specific Memory Slot (03 – 20)
The
Supervisor Code
memory location is called
Slot 01
and the first
User Code
is called
Slot 02
.
• The additional user codes reside in memory slots 03-20.
• To delete a user code from a specific memory slot (03 -20), refer
"RegulatoR Programming Mode"
to enter programming mode.
NOTE:
There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will end
and you will need to enter programming mode again.
1. Place RegulatoR into programming mode (See
"RegulatoR Programming Mode"
).
2. Press
"401"
and then press
ENTER
.
3. Type memory slot to be vacated followed by
ENTER
(for memory slots 03 - 09, you must type leading “0” – e.g. “07” for slot 7).
4. Retype memory slot to be vacated followed by
ENTER.
5. If successful, the
yellow
indicator light will illuminate.
Continue programming or
press 9
and then
ENTER
to exit programming.