FLEXLINE ELECTRONIC PIN LOCK —
INSTRUCTIONS FOR USE
3
www.metro.com
L01-655
REV 01/20
Programming – Introduction
CompX
®
RegulatoR
®
is easy to program and operate.
Type the user code (factory default 1234) and press
ENTER
, then rotate the knob clockwise to unlock the cart.
The supervisor can change operating codes, modes and restore lock settings.
While RegulatoR is easy to program, we highly recommend reading the complete programming instructions
prior to making any changes. Remember to keep track of any programming changes.
Button locations, indicator lights and knob referenced in the programming instructions are shown below:
Follow the directions below to operate (unlock and lock) the standard Self Lock version of RegulatoR:
• Type a valid code, press
ENTER
,
• Rotate knob clockwise,
• Release knob, RegulatoR knob will return to the locking position.
IMPORTANT:
The Flexline cart is not secure until the red locking handle is pushed down to relock the cart !
RegulatoR Programming Mode
To enter programming mode you must know the supervisor code. The default supervisor code is
12345
.
Once in programming mode, multiple changes can be made prior to exiting programming.
NOTE:
There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1. Lock must be in the locked position prior to entering programming mode.
2. Type supervisor code and press
ENTER
.
3. Rotate the knob to the
unlocked
position and press and hold
ENTER
for
"3 seconds"
(
yellow
indicator light will illuminate).
4. You can now let go of the knob.
5. With the
yellow
indicator light illuminated, programming can begin.
Changing the User Code
To change the user code, refer to
"RegulatoR Programming Mode"
to enter programming mode.
The factory default user code is
1234
(User codes must be 4 to 8 digits in length.)
NOTE:
There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1. Place RegulatoR into programming mode (See
"RegulatoR Programming Mode"
).
2. Press
"1"
and then press
ENTER
.
3. Type the current user code and press
ENTER
.
Yellow
- Indicates low battery
or program mode
Indicator Lights
Green
- Indicates button
input and valid code
Red
- Indicates incorrect
entry
CLEAR button
- erases any key input
made in error
ENTER button
- is used to complete code
entry or begin programming
KNOB
- Rotate clockwise to unlock and
counter clockwise to allow relock