FLEXLINE ELECTRONIC PIN LOCK —
INSTRUCTIONS FOR USE
4
www.metro.com
L01-655
REV 01/20
4. Type the new user code and press
ENTER
.
5. Retype the new user code and press
ENTER
.
6. If successful, the
green
indicator light will illuminate for 1 second.
Continue programming or
press 9
and then
ENTER
to exit programming.
NOTE:
Self Lock RegulatoR operates with a fixed code.
Changing the Supervisor Code
To change the supervisor code, refer
"RegulatoR Programming Mode"
to enter programming mode.
The factory default supervisor code is
12345
(supervisor codes must be 4 to 8 digits in length.)
NOTE:
There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1. Place RegulatoR into programming mode (See
"RegulatoR Programming Mode"
).
2. Press
"2"
and then press
ENTER
.
3. Type the current supervisor code and press
ENTER
.
4. Type the new supervisor code and press
ENTER
.
5. Retype the new supervisor code and press
ENTER
.
6. If successful, the
green
indicator light will illuminate for 1 second.
Continue programming or
press 9
and then
ENTER
to exit programming.
Reset Instructions
RegulatoR
®
features a reset code which will restore the default supervisor code and user code. RegulatoR was shipped with reset
stickers; one attached to the back of the RegulatoR and an extra sticker that should be saved in a safe and secure location for future
reference.
NOTE:
To restore the factory default supervisor and user code, type the "
Reset Code"
assigned to the RegulatoR and press
ENTER
.
Programming Security Timeout ON / Security Timeout OFF
WARNING:
Security Timeout ON will disable the RegulatoR from use for 5 minutes when 5 invalid attempts to unlock RegulatoR occur.
During this time, RegulatoR will not unlock with either the valid user or supervisor code.
To change the RegulatoR to Security Timeout ON or OFF, refer
"RegulatoR Programming Mode"
to enter programming mode.
NOTE:
There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1. Place RegulatoR into programming mode (See
"RegulatoR Programming Mode"
).
2. To turn
Security Timeout ON
, type
"11"
and then press
ENTER
.
OR
1. To turn
Security Timeout OFF
, type
"10"
and then press
ENTER
.
2. If successful, the
green
indicator light will illuminate for 1 second.
Continue programming or
press 9
and then
ENTER
to exit programming.
Reset User Code to Factory Default 1234
To reset the
User Code
to the factory default
1234
, refer
"RegulatoR Programming Mode"
to enter programming mode.
NOTE:
There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1. Place RegulatoR into programming mode (See
"RegulatoR Programming Mode"
).
2. Type
"8888"
and then press the
ENTER
button.
3. If successful, the
green
indicator light will illuminate for 1 second.
Continue programming or
press 9
and then
ENTER
to exit programming.