Page 17
Tripod Turnstile Technical Manual
Operating mode and Network address
After installation is complete, the device’s network addresses must be set by changing the Network
Address DIP Switch (
and
) pins positions.
NOTE
Each Metra device must have different address setting.
Switches
#1
and
#2
are reserved for future use and must be set to OFF position (switch down).
Set switch
#3
on
Master
electronics board according devices hardware configuration:
OFF (switch down) indicates no Wristband Capturer is connected.
ON (switch up) indicates the Wristband Capturer is connected.
Set switch
#3
on
Slave
electronics board to OFF position (switch down).
Look up the code for desired Metra NET Network address in the coding table. Set switches
#4
through #8
to indicated positions, where:
0 indicates the corresponding switch is in OFF position (switch down).
1 indicates the corresponding switch is in ON position (switch up).
Coding table:
switch positions
Master
address
Slave
address
switch positions
Master
address
Slave
address
4
5
6
7
8
4
5
6
7
8
0
0
0
0
0
300
332
1
0
0
0
0
316
348
0
0
0
0
1
301
333
1
0
0
0
1
317
349
0
0
0
1
0
302
334
1
0
0
1
0
318
350
0
0
0
1
1
303
335
1
0
0
1
1
319
351
0
0
1
0
0
304
336
1
0
1
0
0
320
352
0
0
1
0
1
305
337
1
0
1
0
1
321
353
0
0
1
1
0
306
338
1
0
1
1
0
322
354
0
0
1
1
1
307
339
1
0
1
1
1
323
355
0
1
0
0
0
308
340
1
1
0
0
0
324
356
0
1
0
0
1
309
341
1
1
0
0
1
325
357
0
1
0
1
0
310
342
1
1
0
1
0
326
358
0
1
0
1
1
311
343
1
1
0
1
1
327
359
0
1
1
0
0
312
344
1
1
1
0
0
328
360
0
1
1
0
1
313
345
1
1
1
0
1
329
361
0
1
1
1
0
314
346
1
1
1
1
0
330
362
0
1
1
1
1
315
347
1
1
1
1
1
331
363
Power-ON
To power button is situated on the connection board.