background image

10

d

isplay

 

of

 

mixer

 

data

Number of mains connections and control panel and frequency converter software version:

•  When the machine is connected to the mains, three values will be displayed in the text field on the panel:

• 

Number of times the machine has been connected, e.g. 

 for three times

•  Control panel software version; first 

 is displayed, then the version, e.g. 

 for version 26

•  Frequency converter software version; first 

 is displayed, then the version, e.g. 

 for version 18

Running time and error log

It is possible to display the time the machine has been on (the motor has been running):

• 

Hit emergency stop and press 

 next to 

.

• 

Time displayed in hours: 0 - 1 - 2 etc.

• 

Deactivate emergency stop to cancel the display.

It is possible to display a log of the errors that have occurred:

• 

Hit emergency stop and press 

 next to 

•  The display shows the latest error first.

• 

To scroll back through the errors, press 

 next to 

; to scroll forward, press 

 next to 

.

• 

The last eight errors can be displayed.

• 

Deactivate emergency stop to cancel the display.

e

rror

 

Codes

 

and

 

possible

 

solUtions

:

For some errors, the control system will show an error code in the display:

  User pressed 

 without raising the bowl to working height.

Solution:

  Raise bowl to working height. 

  User pressed 

 without fitting the safety guard.

Solution: 

Fit the safety guard.

  The frequency converter has overheated.

Solution: 

The error will disappear when the temperature has dropped to an acceptable level.

 

Stop the mixer and reduce the quantity of ingredients in the bowl. When it starts again, select a lower speed

.

  There is an error in communication between the control panel and the frequency converter.

Solution:

  Call the engineer.

  Error in frequency converter.

Solution:  

Call the engineer.

  Thermal sensor in the frequency converter has cut out.

Solution:

  The error will disappear when the temperature has dropped to an acceptable level.

  Intermittent low voltage in the power supply.

Solution: 

The power supply to the mixer should be checked by an expert.

  Intermittent high voltage in the power supply. 

Solution: 

The power supply to the mixer should be checked by an expert.

  The mixer is overloaded because of excessively heavy dough etc.

Solution:

  Reduce the quantity in the bowl; the product may need to be reduced or thinned before the machine is restarted. 

When it starts again, select a lower speed.

Содержание KODIAK CR30

Страница 1: ...dby Phone 45 43 44 22 88 www bearvarimixer com info wodschow dk Denmark K YTT OHJEET 122013 TILAUSNRO 00520 FI Alkuper isen k ytt ohjeen k nn s KODIAK CR30 062015 Onr 00513GB 04 2015 MG4143101 MG41431...

Страница 2: ...not original or specified for this model Failure to comply with instructions in this manual In case of faults with the mixer please contact the supplier The guarantee does not cover damage caused by m...

Страница 3: ...on on Electrical connection which must be followed For the benefit of service staff it should be clear to see when the mains plug to the mixer has been removed from the socket in the wall The cable is...

Страница 4: ...ified in this manual Unless the change is recommended by the manufacturer modifying the machine is prohibited If the machine is fitted with an attachment drive only accessories produced or recommended...

Страница 5: ...pment as follows Bowl trolley Bowl 30 l Hook beater and whip for 30 l bowl Optional accessories Scraper for 30 l bowl if mixer is fitted for a scraper Bowl 15 l Hook beater and whip for 15 l bowl Scra...

Страница 6: ...d against overvoltage The machine should be positioned to allow space for normal use and maintenance Good ergonomics for the user is ensured by the accompanying bowl trolley which eliminates heavy lif...

Страница 7: ...ing hours Safety guard The one piece safety guard is made of transparent plastic The guard is easy to remove and clean The guard can be machine washed at up to 60o and can with stand up to 90o for sho...

Страница 8: ...g times of up to 90 minutes are available The running time will not be reset if is pressed once press once more and it will be reset If no running time is selected the display will show the time elaps...

Страница 9: ...strongly acidic alkaline or saline food products which may attack non coated aluminium Aluminium mixer tools must not be washed in strongly alkaline agents pH between 5 0 and 8 0 Please note that the...

Страница 10: ...me errors the control system will show an error code in the display User pressed without raising the bowl to working height Solution Raise bowl to working height User pressed without fitting the safet...

Страница 11: ...of technical staff The fuse is located in the socket on the back of the machine Remember to remove the mains cable before changing the fuse The fuse can be changed by pulling out the little drawer A...

Страница 12: ...12 Circuit diagram...

Страница 13: ...must not be con nected without an earth as this may com promise the action of the EMC filter by removing the discharge to the ground and may be dangerous for the user For functional and safety rea son...

Страница 14: ...rt hiermit dass diese R hrmaschine D clare que le batteur m langeur ci dessous Verklaart hiermede dat Menger Declaramos que el producto batidora er i overensstemmelse med relevante bestemmelser i Mask...

Страница 15: ...ar h rmed att denna blandningsmaskin Con la presente si dichiara che questo mixer planetaria Deklareerime k esolevaga et Planetaarmikseri Niniejszym o wiadczamy e mikser planetarny vakuuttaa ett t m m...

Страница 16: ......

Отзывы: