5.12.3 Following phases valid for all models
•
Place the manometer;
•
start up the unit by following the instructions in the user's manual;
•
check supply pressure;
•
if the actual pressure is included in the values previously shown in the
"Table 1:
gas categories and pressure values"
, the unit may be turned on, otherwise, contact
the gas utility company;
•
remove the manometer;
•
reassemble the sealing screw (item 3 in Fig. 10 e Fig. 12);
•
check for a good seal (see the preceding chapter
"Gas supply connection"
).