Metel 1-759-226 Скачать руководство пользователя страница 9

www.metel.eu

9/10

Installation manual REV:201301

2G(200M)-2.1.4.E PoE++

LAN-RING System PoE++ Managed Switches

PoE+ managed switches 200M-2.1.4.E

2x FO 200Mbps 

 1x GE 

 4x FE 

 1x RS485/Modbus 

 2x digital input 

 1x relay

input 1

input 2

input 1

input 2

LA

N-R

ING

PC

PC

GE

IO

R

S4

8

5

IO

R

S4

8

5

IO

R

S4

8

5

GE

GE

4x 

PoE+

4x 

PoE+

4x 

PoE+

ORDERING NAME

SUPPLY with PoE/PoE+

SUPPLY without PoE

TAMPER

200M-2.1.4.E

200M-2.1.4.E

200M-2.1.4.E

200M-2.1.4.E-BOX-PoE++

48-57/53-57 VDC 

48-57/53-57 VDC

10-60 VDC / 10-30 VAC

10-60VDC

ne

 

CD - connected fiber detection
ACT - activity detection

P7 - optical port 200Mbps LAN-RING
Tx - 1490nm / Rx - 1310nm

P6 - optical port 200Mbps LAN-RING
Tx - 1310nm / Rx - 1490nm

CD - connected fiber detection
ACT - activity detection

P5 - gigabit Ethernet
10/100/1000 BASE-T
overvoltage protection
30A (8/20us)

USB - local management 
application SIMULand over USB A-B 
cable

P/R - LED POWER / RING
RS485 - LED RS485 TX(R) / RX(G)

RS485
max. 57.6 kbps 
overvoltage protection
 30A (8/20us)

PoE indication
POx - PoE ON
FAx - PoE fault

C

L

A

S

S

 1

 L

A

S

E

R

 P

R

O

D

U

C

T

 !

CD

ACT

CD

ACT

P7

P6

P5

PO4

PO3

PO2

PO1

P4

FA4

FA3

FA2

FA1

P3

P2

P1

USB

IN 1

IN 2

RELAY

A+

GND

B-

P/R

PoE

RS 485

200M-2.1.4.E

RELAY OUT
62,5VA (30W) / 1A / 60V (resistive 
load) current limiter (polytron)

DIGITAL INPUTS
activation by closing to 
GND or by TTL level
„log. 0“ 

0V-0.8V

„log. 1“

2V-5V

overvoltage protection
30A (8/20us)

P1 - P4 Fast Ethernet 
10/100 BASE-T PoE* ports
LED - DUPLEX/COLLISION
ACT - LED ACTIVITY
overvoltage protection 1000A 
(8/20us)

*In application SIMULand can 

select one port for PoE++

Содержание 1-759-226

Страница 1: ...MM or SM fiber Fast Ethernet LEGEND others Gigabit Ethernet supply with PoE 48 56VDC without PoE 10 60VDC 10 30VAC holder DIN35 LOCK for mounting to DIN35 included Ring topology LAN RING Overvoltage p...

Страница 2: ...s The optimum placement of the switch devices and cables connected to the switch is in protection area of a lightning rod i e ZBO0B zone acc to IEC 62305 4 The switches ports are protected in two ways...

Страница 3: ...Opening closing of one or more inputs on other switches and I O modules Function IP watchdog that automatically restarts frozen devices SNMP protocol from integration software e g C4 Everything is adj...

Страница 4: ...s Auto negotiation Auto MDI MDI X and Power down The ports also support supplying of terminal devices over Cat 5e cable acc to IEEE 802 3 af IEEE 802 3at max 15 4W per port 1x Fast Ethernet port with...

Страница 5: ...and optic fiber interruption In non alarm state COM and N C are closed IN OUT digital inputs are activated by closing to GND or by TTL level 0 0 3V log 0 and 2 7V 5V log 1 TTL outputs can be mapped i...

Страница 6: ...not provided select RS485 set Speed and Data bits If the system is provided in the menu no further setting in menu Bus is needed The switch sets it automatically 2 In menu Ethernet set receiving and...

Страница 7: ...you are using If not provided select RS485 set Speed and Data bits If the system is provided in the menu no further setting in menu Bus is needed The switch sets it automatically 2 In menu Ethernet T...

Страница 8: ...kbps overvoltage protection 30A 8 20us PoE indication POx PoE ON FAx PoE fault P P4 Ethernet 10 100 BASE T PoE ports LED DUPLEX COLLISION ACT LED ACTIVITY overvoltage protection 1000A 8 20us LAN RING...

Страница 9: ...1490nm CD connected fiber detection ACT activity detection P5 gigabit Ethernet 10 100 1000 BASE T overvoltage protection 30A 8 20us USB local management application SIMULand over USB A B cable P R LED...

Страница 10: ...www metel eu 10 10 Installation manual REV 201301 2G 200M 2 1 4 E PoE LAN RING System PoE Managed Switches Size 2G a 200M 2 1 4 E PoE...

Отзывы: