Installation manual REV:201301
2G(200M)-2.1.4.E PoE++
LAN-RING System PoE++ Managed Switches
Activation PoE/PoE++ on Fast Ethernet ports
1. In menu
„Ports“
select FE ports FE (
„P1 – P4“
),
where you want to activate PoE supply.
2. Checking the „
Enabled"
to enable PoE power supply
on the port.
3. On one of the ports „
P1 - P4
" You can turn
PoE + + by checking the „
Poe + + Enabled
".
Note: Item
„Ignore discovery“
- pernamently turn on
PoE power supply without detection and classification
of PoE end devices.
The setting consists of the following steps:
1. In menu
„Bus/Mode“
set the system you are using. If not provided select “
RS485
” set „
Speed
“ and „
Data bits
“. If the system
is provided in the menu no further setting in menu
„Bus“
is needed. The switch sets it automatically.
2. In menu
„Ethernet“
set receiving and transmitting addresses in range 239.0.0.0 - 239.255.255.255 (multicast).
topology BUS – set the same receiving and transmitting address on all switches.
topology POINT-to-POINT – set the addresses “crosswise”:
Example: Device 1
receiving address - 239.192.168.2, transmitting address 1 - 239.192.168.3
Device 2
receiving address - 239.192.168.3, transmitting address 1 - 239.192.168.2
LAN-RING
Tx 239.192.168.1
Rx 239.192.168.1
Tx 239.192.168.1
Rx 239.192.168.1
Tx 239.192.168.1
Rx 239.192.168.1
Fast Ethernet
LEGEND
RS485
Gigabit
1x MM or SM fiber
Setting of RS485 transmission in UDP mode (multicast)