Metel 1-759-226 Скачать руководство пользователя страница 1

www.metel.eu

1/10

LAN-RING System PoE++ Managed Switches

2G(200M)-2.1.4.E PoE++

OBJEDNACÍ NÁZEV

KÓD

NAPÁJENÍ

2G-2.1.4.E-BOX-PoE++

1-859-226

10-60VDC/10-30VAC**

200M-2.1.4.E-BOX-PoE++

1-759-226

10-60VDC/10-30VAC**

LAN-RING 2Gbps

GE

IO

IO

IO

R

S4

8

5

IO

R

S4

8

5

IO

IO

R

S4

8

5

IO

R

S4

8

5

R

S4

8

5

6x IO

6x IO

6x IO

6x IO

6x IO

R

S4

8

5

2G-2.1.4.E++

2G-2.1.4.E++

2G-2.1.4.E++

2G-2.1.4.E++

2G-2.1.4.E++

2G-2.1.4.E++

2G-2.1.4.E++

EXP-C

EXP-C

EXP-C

EXP-C

EXP-C

2G-0.1.4.E

2G-0.1.8.E

2G-2.0.1.E

R

S4

8

5

IO

R

S4

8

5

IO

R

S4

8

5

** supply with PoE+ 53-57VDC, without PoE 10-60VDC/10-30VAC

1x MM or SM fiber

Fast Ethernet

LEGEND

others

Gigabit Ethernet

** supply with PoE 48-56VDC, without PoE 10-60VDC/10-30VAC 

* holder DIN35-LOCK for mounting to DIN35 included

▪ Ring topology LAN-RING
▪ Overvoltage protection 1kA on FE ports
▪ 1x RS485 port with support of:

APOLLO, ASSET, ATS, CIAS, DOMINUS, GALAXY,
HUB-PRO, PERIDECT, ROGER, SATEL-ACCO, 
SICURIT-ABSOLUTE, STATION-ONE,  Modbus

▪ 2x digital input
▪ 1x programmable relay
▪ 2x MM/SM universal optical ports with WDM
▪ 1x Gigabit Ethernet
▪ 3x Fast Ethernet port with PoE support (15.4W)
▪ 1x Fast Ethernet port with PoE++ support (90W)
▪ 2 supply inputs
▪ IP Watchdog

▪ SNMP, SMTP, SNTP, IGMP, UPNP support
▪ Support VLAN, 802.1p/q, QoS
▪ Support of logging to SD card
▪ Working temperature from – 40°C to +70°C

BOX*

BOX + DIN35-LOCK*

Содержание 1-759-226

Страница 1: ...MM or SM fiber Fast Ethernet LEGEND others Gigabit Ethernet supply with PoE 48 56VDC without PoE 10 60VDC 10 30VAC holder DIN35 LOCK for mounting to DIN35 included Ring topology LAN RING Overvoltage p...

Страница 2: ...s The optimum placement of the switch devices and cables connected to the switch is in protection area of a lightning rod i e ZBO0B zone acc to IEC 62305 4 The switches ports are protected in two ways...

Страница 3: ...Opening closing of one or more inputs on other switches and I O modules Function IP watchdog that automatically restarts frozen devices SNMP protocol from integration software e g C4 Everything is adj...

Страница 4: ...s Auto negotiation Auto MDI MDI X and Power down The ports also support supplying of terminal devices over Cat 5e cable acc to IEEE 802 3 af IEEE 802 3at max 15 4W per port 1x Fast Ethernet port with...

Страница 5: ...and optic fiber interruption In non alarm state COM and N C are closed IN OUT digital inputs are activated by closing to GND or by TTL level 0 0 3V log 0 and 2 7V 5V log 1 TTL outputs can be mapped i...

Страница 6: ...not provided select RS485 set Speed and Data bits If the system is provided in the menu no further setting in menu Bus is needed The switch sets it automatically 2 In menu Ethernet set receiving and...

Страница 7: ...you are using If not provided select RS485 set Speed and Data bits If the system is provided in the menu no further setting in menu Bus is needed The switch sets it automatically 2 In menu Ethernet T...

Страница 8: ...kbps overvoltage protection 30A 8 20us PoE indication POx PoE ON FAx PoE fault P P4 Ethernet 10 100 BASE T PoE ports LED DUPLEX COLLISION ACT LED ACTIVITY overvoltage protection 1000A 8 20us LAN RING...

Страница 9: ...1490nm CD connected fiber detection ACT activity detection P5 gigabit Ethernet 10 100 1000 BASE T overvoltage protection 30A 8 20us USB local management application SIMULand over USB A B cable P R LED...

Страница 10: ...www metel eu 10 10 Installation manual REV 201301 2G 200M 2 1 4 E PoE LAN RING System PoE Managed Switches Size 2G a 200M 2 1 4 E PoE...

Отзывы: