25
O
PER
ATIN
G MANU
AL
Panbrake
NC-89 Contr
oller Operation
W
ARNING:
Please r
ead the “Panbrake Hydraulic Clamp Manual” befor
e clamping.
Angle SV
:
Desired programmed angle.
Operation:
Move Arr
ow to
Angle SV
, clear value
, enter desir
ed angle value. Example: 5 = 5
º,
and pr
ess
.
Angle PV
:
Actual position of apron.
Operation:
Angle PV is a digital r
eadout for the apr
on angle as the apr
on moves. This is visual only and can not be modified.
Dwell Time:
Desired time apron will dwell after it has reached Angle SV
. Auto function only
Operation:
Move Arr
ow to
Dwell Time
, clear value
, enter desir
ed value. Example: 2 = 2 seconds, and pr
ess
.
Open Height:
Desired height the clamp opens after apron returns to zero. Auto function only
Operation:
Move Arr
ow to
Open Height
, clear value
, enter desir
ed value. Example: 3 = 3 seconds, and pr
ess
.
Clamp Operation:
See “Man-06 (Panbrake-Hyd-Clamp-Setup-Operation).pdf” manual befor
e clamping material.
Manual Bend:
Switch mode to manual. Example: Enter 90
º
in
Angle SV
. Clamp material and use the Up Manual Button to bend
material. Button can be r
eleased at any time and apr
on will stop. NC-89 with stop apr
on at 90
º
. Release button and bend mor
e/less
or r
etur
n back to 0
º
and unclamp with foot pedal.
W
ARNING:
The apr
on will automatically bend up once the
start button is pr
essed.
Auto
Bend:
Switch
mode
to
Auto.
Example:
Enter
90
º
in
Angle
SV
,
Enter
2
sec
in
Dwell
Time,
Enter
3
sec
in
Open
Height
. Clamp
material
and pr
ess
gr
een
start
button
on
NC-89.
Apr
on will
automatically
bend up
to
90
º,
dwell for
2
seconds,
retur
n
to
0º and
then
clamp will open for 3 seconds. Job complete
.
Emergency Stop:
Pr
ess this button to stop operation at any time in case of emer
gency in manual or auto mode.
Clear
Stop
Start
Manual
Auto
Arr
ow
Manual
Bend
Up / Down
Emergency
Stop