10. DIAGNOSTICS I4.0
The new advanced Link Regtronic IO-Link diagnostics, called Regtronic I4.0, provides conventional maintenance with a powerful tool of analysis to
ensure reliable, safe and long-lasting operation of the production units.
Maintenance operations are rationalised and optimised through the development of preventive maintenance to:
- prevent breakdowns;
- intervene preventatively to avoid plant shutdowns;
- have all the information relating to operation of equipment in real time;
- monitor the end-of-life of component parts;
- optimize the management of spare parts in the warehouse.
All this makes it possible to convert the data collected into concrete actions, using standard BOXI IO-Link units, without the need for additional
modules.
10.1 Description of Regtronic I4.0 functions
System data
- unit activation counter;
- total working time;
- voltage too-low alarm counter;
- voltage too-high alarm counter;
- alarm for incorrect parameters;
- pressure sensor faulty.
Solenoid pilot data
The following data is permanently stored for each of the two solenoid pilots:
- cycle counter;
- total solenoid pilot activation time counter;
- activation of a report indicating operating cycle exceeding 60%;
- Short-Circuiting Alarm counter;
- Circuit-Open Alarm counter.
Data in hexadecimal format is available as system variables using the IO-Link tools made available by the manufacturers of Master modules, such as
the Siemens Function Block IO_LINK_DEVICE [FB5001]. Refer to the relevant Siemens manual for correct use.
Parameter list
System data
Function
Index
SubIndex
Format
Aggregate data
81
0
12 byte - 6 fields
Number of switches ON
1
UINT 32 bit
Total operating time (hours)
2
UINT 32 bit
Number of voltage too-high alarms
3
UINT 8 bit
Number of voltage too-low alarms
4
UINT 8 bit
Number of wrong parameter alarms
5
UINT 8 bit
Number of disconnected pressure sensor alarms
6
UINT 8 bit
Solenoid pilot data
Function
Index
SubIndex
Data type
P IN Average operating cycle exceeding 60%
66
1
UINT 8 bit
P IN Number of short circuit alarms
2
UINT 8 bit
P IN Number of interrupted circuit alarms
3
UINT 8 bit
P IN Total number of cycles
4
UINT 32 bit
P IN Total activation time
5
UINT 32 bit
P OUT Average operating cycle exceeding 60%
6
UINT 8 bit
P OUT Number of short circuit alarms
7
UINT 8 bit
P OUT Number of interrupted circuit alarms
8
UINT 8 bit
P OUT Total number of cycles
9
UINT 32 bit
P OUT Total activation time
10
UINT 32 bit
Содержание REGTRONIC IO-Link
Страница 1: ...REGTRONIC IO Link MANUALE D USO REGTRONIC IO Link USER MANUAL...
Страница 15: ...15 NOTE Esempio di visualizzazione in Siemens S7 PCT...
Страница 16: ...16 NOTES...
Страница 30: ...30 NOTES Example of display in Siemens S7 PCT...
Страница 31: ...31 NOTES...
Страница 32: ...32 www metalwork eu M0030212 IT_EN IM00_01 2020 NOTES...