27
8.2 Installation without using the IODD configuration file “MetalWork-REGTRONIC-20190613-IODD1.1”
Some Master modules do not use the IODD file for the configuration of operating parameters.
In this case, the device must be configured manually.
8.3 Example of configuration with a SICK Gateway Profinet/ IO-Link Master
Profinet Device Configuration
Install the Gateway in the Profinet Controller development environment.
Configuring the selected IO-Link port, with 2 byte Input and 2 byte Output (I/O_2/_2byte)
First load the Controller project and connect the Regtronic to the associated IO-Link port.
Parameter Configuration
The parameters of the unit can be configured by accessing the Gateway via a browser, by typing in the IP address in the bar, which can be
retrieved in the accompanying documentation together with Login and Password.
Selecting the port to which the Regtronic has been connected will display all the data and parameters stored in the device.
The Process Data area displays the state of Inputs.
The operating parameters can be entered in the Parameter Data area. The parameters must be entered using the specific index indicated on page 11.
Содержание REGTRONIC IO-Link
Страница 1: ...REGTRONIC IO Link MANUALE D USO REGTRONIC IO Link USER MANUAL...
Страница 15: ...15 NOTE Esempio di visualizzazione in Siemens S7 PCT...
Страница 16: ...16 NOTES...
Страница 30: ...30 NOTES Example of display in Siemens S7 PCT...
Страница 31: ...31 NOTES...
Страница 32: ...32 www metalwork eu M0030212 IT_EN IM00_01 2020 NOTES...