28
9. TECHNICAL DATA
9.1 IO-Link ELECTRICAL CONNECTION
TECHNICAL DATA
Fieldbus
IO-Link version 1.1
Communication speed
Kbps
230.4 (COM3)
Vendor ID / Device ID
1046 (hex 0x0416) / 32 (hex 0x000020)
Minimum cycle time
ms
2.8
Process data length
2 byte of Input / 2 byte of Output
Supply voltage range
VDC
from 18 to 30
Maximum admissible voltage
VDC
32 *
Protection
Module protected from overload and polarity inversion. Outputs protected from overloads and short-circuits.
Connections
Fieldbus: M12 male, A-coded - Port Class A.
Diagnostics
IO-Link: via local LED lights and software messages.
Power supply current absorption
Max 150 mA to 18 V
* IIMPORTANT! Voltage greater than 32VDC will damage the system irreparably.
TECHNICAL DATA
REGTRONIC
REGTRONIC
NEW DEAL
REGTRONIC
300
REGTRONIC
400
Threaded port
M5
1/8’’
1/4’’
3/4’’
1’’
1/2’’
3/4’’
1’’
1’’
1 1/4’’ 1 1/2’’
2’’
Fluid
Filtered, unlubricated air. The air must be filtered at least 10 µm
MIN inlet pressure
bar
Regulation pr 1 bar
MAX inlet pressure
bar
11
Temperature range
°C
from 0 to 50
Pressure regulation range
bar
from 0.05 to 10 (settable full scale and minimum pressure)
Flow rate at 6.3 bar ∆P 0.5
Nl/min
10
1300
1500
10000
4500
18000
20000
Flow rate at 6.3 bar ∆P 1
Nl/min
10
1450
1700
13000
7000
-
-
Exhaust flow rate at 6.3 bar with 0.1 bar overpressure
Nl/min
2
600
1300
1800
250
400
400
Exhaust flow rate at 6.3 bar with 0.5 bar overpressure
Nl/min
9
1000
1500
2000
500
850
850
Weight
kg
0.2
0.38
0.38
1.3
1.5
5
5.8
Class of protection
IP 65
Linearity
≤ ± 0.5% (Full scale)
Hysteresis
≤ ± 0.2% (Full scale)
Repeatability
≤ ± 0.2% (Full scale)
Sensitivity/Dead-band
setting range 10 to 300 mbar
Output pressure (display version)
Accuracy
≤ ± 0.3% (Full scale)
Unit of measurement
bar, MPa, psi
Minimum resolution
0.01 bar - 0.001 MPa - 0.01 psi
Temperature characteristics
max 2 mbar / °C
Response time with ∆P =1 bar
volume 100 cc
volume 1000 cc
from 6 to 7 bar
s
0.5
0.2
0.3
0.45
0.35
from 7 to 6 bar
s 0.55
0.3
0.3
0.45
0.7
Installation position
In any position
Notes
The features shown refer to the static condition only. With air consumption on the output side, the pressure may vary.
Содержание REGTRONIC IO-Link
Страница 1: ...REGTRONIC IO Link MANUALE D USO REGTRONIC IO Link USER MANUAL...
Страница 15: ...15 NOTE Esempio di visualizzazione in Siemens S7 PCT...
Страница 16: ...16 NOTES...
Страница 30: ...30 NOTES Example of display in Siemens S7 PCT...
Страница 31: ...31 NOTES...
Страница 32: ...32 www metalwork eu M0030212 IT_EN IM00_01 2020 NOTES...