NOTE:
AUTO IRIS and SHUT+AUTO IRIS difference
•
Use DC lens and setting to AUTO IRIS mode for normal condition application
environments. The IRIS level will be controlled by camera brightness.
•
Use DC lens and setting to SHUT+AUTO IRIS mode for high light application
environments. The exposure will be controlled by AES or the DC Iris. The iris
level will be controlled by camera brightness.
If you use Manual lens, then select MANUAL mode. The shutter speed is variable
from 1/50(1/60)sec to the 1/10Ksec and the AGC is selectable depending on your
environment condition.
4.3 WHITE BAL
WHITE BALANCE controls color on the screen. The default is ATW. The color
temperature range is 2500°K - 9500°K. Move the joystick control LEFT or RIGHT to
select ATW(Auto White Balance), PUSH, PUSH LOCK, USER1, USER2, Anti CR(Anti
Color Rolling Suppression) or MANUAL mode. Enter the ATW submenu as shown
in the figure. Move the joystick control UP or DOWN to select the desired value.
ATW(Auto White Balance) select when the scene illumination varies between indoor
scenes and outdoor scene lighting.
<Notice>
When setting different value of ATW FRAME and application environment, the color
temperature range of white balance will be changed. The color temperature range of
X0.50 of ATW FRAME will be smaller than X.20.
If selected MANUAL mode, you can adjust LEVEL from 15 to 69.
If selected USER1 or USER2 mode, you can adjust B-GAIN and R-GAIN value from 0
to 255.
MENU SETTING
9
HIGH LUMINANCE
MODE
AUTO IRIS
BRIGHTNESS
024
LOW LUMINANCE
MODE
AGC
BRIGHTNESS
x0.25
MODE
OFF
SHUTTER
1/50(1/60)
AGC
6.0
SPEED
171
DELAY CNT
152
ATW FRAME
X0.50
ENVIRONMENT
INDOOR