7I43 27
SUPPLIED CONFIGURATIONS
USBIOPR8
EXAMPLE RPC COMMAND LIST
This is an example stored RPC command list. Note RPC command lists must start
at a RPCPitch boundary in the RPC table but an individual RPC list can extend until the
end of the table. This particular RPC example contains 3 LBP commands and uses 11
bytes starting at 0x0050 (RPC5 for 0x10 pitch RPC table)
Command1. Writes two data bytes to port 0x10, 0x11 with 2 data bytes supplied by host
Command2. Reads two data bytes from port 0x12,0x13
Command3. Writes a single byte (0xAA) to port 0x14, data contained in RPC table
COMMAND BITS
CT1
CT0
WR
RID
I
AS
DS1
DS0
LBPWrite: 2 add 2 data
0
1
1
0
0
1
0
1
Write Address LSB
0
0
0
1
0
0
0
0
Write Address MSB
0
0
0
0
0
0
0
0
LBPRead: 2 add 2 data
0
1
0
0
0
1
0
1
Read Address LSB
0
0
0
1
0
0
1
0
Read Address MSB
0
0
0
0
0
0
0
0
LBPWrite 2 add 1 data
1
0
1
1
0
1
0
0
Write Address LSB
0
0
0
1
0
1
0
0
Write Address MSB
0
0
0
0
0
0
0
0
Write Data
1
0
1
0
1
0
1
0
Terminator
0
0
0
0
0
0
0
0
The data stream for this RPC would consist of these 3 bytes:
COMMAND BITS
CT1
CT0
R5
R4
R3
R2
R1
R0
RPC 5
1
0
0
0
0
1
0
1
Data 0 for Command 1
0
1
0
1
0
1
0
1
Data 1 for Command 1
1
1
0
0
1
1
0
0