58
Service & Parts Manual original Instructions
Part Number 32Z3810GB
Issue 1
COMMISSIONING
Commissioning the oven
26
Initial installation
26.1
Unpack the Oven and check for damage.
1
Check Oven Accessories.
2
Check location will provide adequate Ventilation.
3
Locate Oven onto a strong, level, non-flammable
4
Surface.
Remove panels & check all wiring and components for
5
security.
Refit panels.
6
Position the Oven with a minimum air gap of 50mm,
7
sides & rear.
Check Electrical supply and connect.
8
Place a container of water within the oven and switch
9
it on.
Record Model version & check against serial plate.
10
Record BTS (UI) version.
11
Record SRB version.
12
Record Serial Number & check against serial plate.
13
Enter Service Mode.
14
Record Voltage & Frequency.
15
Record Magnetron Current Draw.
16
Check for Microwave leakage.
17
Record Heater current.
18
Check door opening on display.
19
Check filter removal on display.
20
Check fan speed.
21
Turn off the oven and remove the water.
22
Switch on oven and run up to temperature.
23
Operate Oven, Cooking a Standard Batch.
24
Supply User information & contact details to Customer.
25
Instruct Users with an Overview of the equipment,
26
Operation & Safety (Hazards).
Complete Service Report.
27
After Service
26.2
Complete the following checks after the Oven has been
Serviced/Repaired/Tested before connecting to the
mains electricity power supply:
All internal electrical connections are correct (see
26.2.1
wiring diagrams).
All wiring insulation is correct and is not touching any
26.2.2
sharp edges.
All grounding connections are electrically and
26.2.3
mechanically secure.
All door safety interlocks are secure and mechanically
26.2.4
sound.
The door activates all of the door interlock switches
26.2.5
and in the correct order.
The door operation is smooth, and the arms run freely
26.2.6
in the slots.
The temperature sensor is correctly connected to the
26.2.7
SRB.
The casing is securely refitted with no trapped wires.
26.2.8
Before finishing a service call, recheck the following
points:
Run the Recommission tests to ensure the oven is
26.2.9
functioning correctly and the touch screen is working.
Microwave emissions are below permissible limit of
26.2.10
5mW/cm².
The power output of the oven is checked in
26.2.11
accordance with the procedure.
The oven has correct 50mm (2 inches) air gap all
26.2.12
round and 50mm (2 inches) above. Air flow should not be
restricted.
Complete the Service Report.
26.2.13