TESTING
COMPONENT
S
A
A
Soak Test
16.8
Checking the oven cavity integrity.
Procedure:
Place an oven/microwave safe container with
16.8.1
approx. 2 litres of water into the oven.
Close the oven door and select ‘Soak Test’ (A)
16.8.2
from the Service mode oven tests (maximum oven
temperature, 50% microwave power, maximum fan
speed).
Run the test (30 minutes), carefully checking the
16.8.3
oven casing, joints and door seal for signs of steam or
water escaping from the oven cavity.
If necessary, rectify any leaks and repeat the test.
16.8.4
Safely remove the container from the oven.
16.8.5
Recommission Test
16.9
The Recommission tests are performed following
the completion of a service or repair to ensure
the oven is operational before handing back to
the customer.
Some of the tests have a countdown timer where
failing to carry out a test within the time limit will
cause a test failure and the Recommission test will
have to be restarted.
Procedure:
Select ‘Recommission Test’ (A) from the service
16.9.1
mode oven tests and follow the on screen instructions
to perform the tests. Do not select the red ‘X’unless
you want to stop the test.
After a test has successfully passed, select OK to
16.9.2
continue.
When all the tests have been successfully
16.9.3
performed the display shows the Recommission test
has passed, select OK to confirm.
In the event of a Recommission test failure,
16.9.4
the detail will be recorded in the Error log. Any error
should be rectified and the Recommission test run
again.