SUBJECT
HOW
HOW OFTEN
Cleaning the outside of the appliance
Clean the external part with a damp cloth, do not use solvents or abrasive detergents. Monthly
Replacing the CO2 cylinders
Follow the instructions provided in paragraph 6.2.
When the manometer falls
below 1 bar.
Cleaning the water collection tray
Clean the tray and remove any residue.
Weekly
&OHDQLQJWKHFRROLQJFRQGHQVHU¿J
Remove all dust and dirt with a domestic vacuum cleaner or similar appliance.
Do not use compressed air jets.
Do not use wire brushes.
Monthly
Water replacement in the ice bank tank
Switch the apparatus off and wait about 1 hour for it to defrost.
Empty the water using the level and basin unloading tube
P
(see section 5.3.2)
Restore the water level in the ice bank tank as described in the INSTALLA-
TION chapter.
If the machine has been
turned off for a long time
Power lead
Check the condition and intactness of the power lead.
Water connection check
Check the condition and intactness of the water supply pipe.
Check for any leak.
&OHDQLQJWKHPHFKDQLFDOZDWHU¿OWHU723
models)
'LVDVVHPEOHWKHLQOHWSLSH¿WWLQJSXOOWKH¿OWHUXVLQJSOLHUVDQGUHPRYHDQ\
LPSXULWLHV¿J
Every month
Cleaning the water dispensing spouts
Remove the steel nozzle using the appropriate spanner and eliminate all the
OLPHVWRQHZLWKDIRRGGHVFDOLQJVROXWLRQ¿J
Depending on the hardness
of the water from the mains
'HFDOFL¿FDWLRQWKHPDFKLQH
&KHFNDQGLIQHFHVVDU\GHVFDOLQJWKHZDWHUVXSSO\KRVHDQG¿OWHU
Annually
7 ROUTINE
MAINTENANCE
GB
5LVHUYDWRDGRSHUDWRULTXDOL¿FDWL5HVHUYHGWRTXDOL¿HGRSHUDWRUV)UTXDOL¿]LHUWH%HWULHEHQ5HVpUYpDX[SHUVRQQHOTXDOL¿p5HVHUYDGRDWpFQLFRVFDOL¿FDGRV
Maintenance operations should be carried out by
a
TXDOL¿HGSURIHVVLRQDO
25.1
25.2
17
Содержание COSMETAL H2OMY IN F
Страница 9: ...HANDBOOK SECTION II 5HVHUYHG WR TXDOL HG RSHUDWRUV 9 ...
Страница 21: ...21 ...