During connection of the appliance to the mains water
supply , all pre -exixting tubes , gaskets and
joints placed between the appliance and the
water mains connection must be replaced with
new material to avoid contamination.
6-7cm
6-7cm
5
5.1
6
8
7
P
K
,IWKHPDLQVSUHVVXUHLVEHORZEDURUWKHÀRZUDWHLVOHVVWKDQOPLQ
¿WDGHYLFHFDSDEOHRILQFUHDVLQJWKHPDLQVSUHVVXUHH[ERRVWHUSXPS
or equivalent system).
N.B.: the pressure is especially important for those water
FRROHUV¿WWHGZLWKDFDUERQDWLRQGHYLFH
If the mains water pressure exceeds 3 bars, predispose a pressure re-
ducer capable of reducing the latter to the 1÷3 range.
7KLVZDWHUGLVSHQVHUFDQEHHTXLSSHGZLWKD:$7(5%/2&.DQWLÀRRG
-
LQJGHYLFHRSWLRQDOWRSUHYHQWDQ\DFFLGHQWDOZDWHUOHDNV¿J2QFH
WKH:$7(5%/2&.GHYLFHKDVLQWHUYHQHG¿WWLQJ
K
should be disassem-
bled and button
P
pressed to reset the device.
If instead of being connected directly to the aqueduct the machine is
connected to an autoclave pump, then it is necessary to install above the
ZDWHUVXSSO\DQ$17,6+2&.GHYLFHWRSUHYHQW³ZDWHUKDPPHUV´¿J
5.1 POSITIONING
THE
APPLIANCE
Position the appliance in the point of installation, away from sources of
eat and direct sunlight. We also advise against installing the appliance
outdoors and in very damp rooms.
Install the machine under the sink, keeping the vent
C
completely clear.
Do not put anything in the way that could prevent or restrict the circula-
WLRQRIDLU¿J
The appliance should be positioned in such a way as to leave approximate-
ly 6 ÷ 7 cm of space free for air to circulate freely. Special ventilation grills/
slits must be prepared in the undercounter model’s housing compartment
WRIDYRXUGLVSRVDORIWKHKHDWSURGXFHGE\WKHUHIULJHUDWLQJFLUFXLW¿J
Make sure the water cooler is resting fully on all four supporting feet.
5.2 WATER CONNECTION TO THE MAINS
Before making the water connection, make sure the mains water pressure
is between 1 and 3 bars.
5 INSTALLATION
GB
10
Содержание COSMETAL H2OMY IN F
Страница 9: ...HANDBOOK SECTION II 5HVHUYHG WR TXDOL HG RSHUDWRUV 9 ...
Страница 21: ...21 ...