MOUNTING THE EVERCHARGE STANDBY POWER UNIT (SPU) (OPTIONAL ACCESSORY 6
)
• The SPU can be mounted to either the ceiling or a wall within .9 m (3') of the opener.
• Position the SPU as desired to a structural support (ceiling joist or wall stud).
• Attach the SPU to the support using the mounting holes on either side of the SPU.
• Secure the SPU using the 1-1/2" lag screws (2) provided with the SPU unit.
• Connect the SPU cord into the connector on the bottom of the opener.
• Follow all instructions included with the CM475 unit to test for proper operation and testing of the SPU.
SPECIAL FEATURES (OPTIONAL ACCESSORIES)
1. Solenoid roller door lock (SRDLK01)
2. 24VDC power output for external devices
3. Voltage free door monitoring output
4. The Protector System
TM
IR Beams - C77
5. Motion detecting control panel - C98
6. Standby Power Unit (battery backup CM475)
7. Tear out cable entries (
∅
16mm)
8. Flashing light FLA24-2ANZ (door not closed indicator only)
18
If the wire supplied with the
solonoid roller door lock (1)
is not long enough, the cable
will need to be extended
using a 2 pair wire of an
equivalent size. Ensure that
the wire polarity is matched
and connections are secure
and insulated.