1. Instruction manual (this document)
2. Stop collar
3. Clamp bracket
4. Release handle, cord and risk of entrapment card
5. Transmitters (2)
6. Wireless wall button
7. Hardware bag
8. Clamp plate
9. Warning label and risk of entrapment label
CARTON INVENTORY
1
(or work platform, not shown)
TOOLS REQUIRED
2
1. Ladder or work platform (not shown)
2. Adjustable wrench for U-bolts already installed
on the door
3. 8mm socket, 10mm socket and 13mm extended
socket and socket wrench
4. 300mm socket extension (for minimum side-room
installations)
5. Drill and 5.5mm drill bit
6. Philips-head screwdriver
7. Marker pen
8. Hoist or similar device to safely lift & support door
(not shown)
DOOR REQUIREMENTS
3
Ensure that there is at least 45mm from the edge of the curtain to the edge of the bracket. If the roller door
drum is on the edge of the curtain or is a smaller diameter, additional clearance may be required.
Different drum and bracket types may result in the minimum side room clearance not being possible, drum
extensions or adaptors may be required. Ensure there is a power point near the opener.
95mm
95mm
Minimum distance from
edge of curtain to edge of
door bracket 45mm
Alternate
clamping method
(Onto Axle only)
Preferred clamping
method
(Direct to Wall
Bracket)
The maximum allowable door height is 5.5m (light commercial door) with a maximum curtain area of 25m² (door
height in metres multiplied by the width in metres). The door must be of continuous corrugated sheet construction,
spring balanced & of a mass not exceeding 250kg. Door axle diameter must not exceed 35mm.
2